Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
1. Adjusting Tape Speed
Requirements Test Tape: TTA-100 (3kHz) Test Point: HP OUT Adjustment Point: SFR 1 1) Insert the test tape (TTA-100), FWD play back the centre of the tape and adjust the SFR1 until it becomes 3,000Hz±10Hz. 2) RVS playback and check that ±45Hz is added according to the FWD speed.
2. Checking WOW & FLUTTER
Requirements Same as number 1. 1) Set the indicator to JIS and the mode to W RMS (WTD) of the WOW & FLUTTER. 2) Playback the centre of the test tape (TTA-100) and check that it is below 0.15%.
3. Adjusting Head Azimuth
Requirements Test Tape: TTA-300 (10kHz) Test Point: SP OUT (Lch/Rch) Adjustment Point: Head Azimuth Screws 1) Set the V mode of the oscilloscope to ADD. 2) Insert the test tape (TTA-300), FWD playback the centre of the tape and adjust, using the head azimuth screws until the waveform of the oscilloscope has reached the maximum when playing back at 10khz. 3) Reverse the tape, RVS playback and adjust, using the head azimuth screws until the waveform of the oscilloscope has reached the maximum. 4) After the adjustment, bond lock (1600B) the screws.
4. Checking Playback Frequency Reponse
Requirements Test Tape: TTA-300 (315Hz/10kHz) Test Point: SP OUT (Lch/Rch) 1) Insert the test tape (TTA-300) and playback 315Hz and 10kHz. 2) Use the 315Hz output level as a standard, check that the 10kHz level is within ±3dB.
5. Checking Playback Sensitivity
Requirements Test Tape: TTA-200 (400Hz) Test Point: SP OUT (Lch / Rch) 1) Insert the tape (TTA-200) and playback. 2) Check that the output level is within 2.8V±3dB.
6. Adjusting the REC / PB Frequency Response
Requirements Test Tape: TTA-602 Test Point: SP OUT (Lch / Rch) Input Point: AUX (1kHz / 10kHz) Adjustment Point: SFR851 (Lch), SFR852 (Rch) 1) Attenuate the output of the attenuator by 20dB to prepare for No.3 2) Insert the test tape (TTA-602) and record 1kHz and 10kHz alternately from AUX. 3) Playback the tape, adjust SFR851 (Lch) / SFR852 (Rch) until the playback output level of 10kHz is within ±0.5dB according to the standard when the playback output level of 1kHz is used as the standard.