|
Who's Online
There currently are 5873 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Very satisfied! I was searching for several days, but nope; till I discovered your webside and there it was at a very reasonable price. Keep up the good work!
Paul
Flanders
;
Generally speaking good copy; a few pages too hard contrast...
Good service and communication.
;
I purchased the unit from a private party and the original owners manual was not available. Having the ability to download it was extremely helpful and clarified operating the equipment immensely. This is a complicated unit and without the manual I would not have been able to maximize it's potential. Thank you.
;
Being a user of older radios of many kinds, preferring them over more modern rigs, this manual was invaluable in the programming of my two. I now know for certain what the assorted buttons functions are, and am very grateful to have found this excellent site. Many thanks for your assistance, Tony.
;
Clear and easy to read. All details as expected. Price acceptable , and quick delivery.
One type of fire front and fret suggested is shown in Fig 1, this has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes. If other fronts and frets are to be used they must have a minimum open area in the fret of 20 sq. cms and 60 sq. cms in the front. See Fig 1 This appliance is fitted with an Oxy-pilot which in the event of the flue being blocked, or hazardous conditions causing the appliance to spill products of combustion, will shut �OFF� the gas supply to the appliance. If the sequence is repeated the appliance must be turned �OFF� and not used until expert advice has been obtained. Clearance to Side Minimum clearance required to any combustible material to the side of the appliance must be 150mm. Clearance to Shelves Minimum clearance to the underside of a 150mm deep combustible shelf from the hearth must be 790mm, add 12.5mm to this dimension for every 25mm increase in the depth of the shelf. To light the appliance Remove the fret (controls cover) to gain access. Press and turn the gas control knob anti-clockwise until the indicator dot is opposite IGN. Keep the gas control fully depressed. Press and release the piezo igniter until the pilot flame situated in the centre behind the simulated coal front has lit. Keep the gas control depressed for a further 10 to 15 seconds. Release the gas control and check that the pilot flame remains lit. Refer to Fig 2 to view pilot. Note: For convenience the unit can be operated with the pilot only, i.e. with the control knob set in the IGN position. Push in the gas control slightly and turn anti-clockwise so that the indicator dot is at the required setting. Replace the fret (controls cover). To turn off the appliance and pilot, turn the gas control clockwise from any position - until the indicator dot is opposite �OFF�. IMPORTANT: After turning OFF or if the pilot and the appliance goes out for any reason, wait for three minutes before attempting to relight. Dismantling the Fire Bed for Cleaning Allow the appliance to cool for 1 hour before handling any components. Remove the coals, lift off the simulated coal front and the coal support shelf. Take out the lower fibre back and side cheeks. Once all the fibre components have been removed from the firebed check that no debris has fallen in or lodged the burner slots (both front and rear). If any debris is present it may be easily removed by using a small piece of thin cardboard to ease out any foreign matter. Be sure to remove the cardboard after use. Should any soot accumulation become excessive, the fuel effect pieces should be removed from the fire for cleaning. Cleaning should be carried out in a well-ventilated area or in the open air, by gently brushing with the pieces held away from your face so that you avoid inhaling the dust. We do not recommend the use of a normal domestic vacuum cleaner, which may blow dust back into the air. Any sooty deposit on the thermocouple probe can be cleaned of using a non-fluffy cloth.
Page 3
|
|
|
> |
|