Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
 ;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
 ;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
 ;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
CD SECTION
Note: 1. CD Block is basically constructed to operate without adjustment. Therefore, check each item in order given. 2. 3. 4. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. Use an oscilloscope with more than 10M� impedance. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. Adjust the focus bias adjustment when optical block is replaced.
RF Level Check
CD DECODER board TP (RF) CN12 (VC) oscilloscope
Procedure : 1. 2. 3. 4. Connect oscilloscope to test point TP (RF) on CD DECODER board. Turned Power switch on. Put disc (YEDS-18) in and playback. Confirm that oscilloscope waveform is clear and check RF
5.
Focus Bias Adjustment
DC voltmeter CD DECODER board CN12 FEO VC
signal level is correct or not. Note: Clear RF signal waveform means that the shape ��� can be clearly distinguished at the center of the waveform.
VOLT/DIV: 200 mV TIME/DIV: 500 nS level: 1.0 �0.2 Vp-p
+0.3
+ �
Procedure: 1. Connect DC voltmeter to test point CN12 (FEO), (VC) on CD DECODER board. 2. Turned Power switch on. 3. Put disc (YEDS-18) in and stop. 4. Adjust VR01 so that the DC voitmeter reading is 0 ± 20 mV. Adjustment Location: CD DECODER board
Adjustment Location: CD DECODER board
Focus Gain Adjustment (VR02) This gain has a margin, so even if it is slightly off. There is no problem. Therfore, do not perform this adjusment. Please note that it should be fixed to mechanical center position when you moved and do not know original position.
Adjustment Location [CD DECODER BOARD] � Component side �
Focus Gain CN12 VR02 IC03 VR01 R07 Focus Bias IC01 RF Level