1-3. Replacing CCD Unit
1-3-4. Positioning Adjustment for Filter Knobs
Installing the filter knobs, be sure to perform the following adjustment. 1. Rotate the outer knob shaft until the cross filter can be seen from the lens mount. 2. Align the CC filter knob number A with the mark on the front panel and tighten the two setscrews. Tightening torque: 20 x 10_2 N.m (2.0 kgf.cm) 3. Rotate the CC filter knob and check that it moves smoothly. 4. Rotate the inner knob shaft until the clear filter (straight through filter) can be seen from the lens mount. 5. Align the ND filter knob number 1 with the mark on the front panel and tighten the two setscrews. Tightening torque: 20 x 10_2 N.m (2.0 kgf.cm) 6. Rotate the ND filter knob and check that it moves smoothly.
Setscrews (WP2 x 3) Setscrews (WP2 x 3)