Who's Online
There currently are 6037 guests and 6 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The service manual is as described and received the link to the download sooner than expected. Great service, quality product. This site is a big help in the electronics repair business.
;
Il service manual molto accurato. Rapidi nella risposta
;
Quick site processing. A complete and very useful manual with all details. Thank you!
;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
3.5.8 Sub DET [HR-S6700KR]
Signal Mode Equipment Adjustment part Specified value Adjustment tool (A) (B) (C) (F) (G) (H) � RF signal (sound carrier: S2) � Tuner � EE � Audio level meter � IC1501 pin 26 � T1501 (SUB DET) � Minimum distortion � LPF (30 kHz), HPF (400 Hz)
3.6 SYSCON CIRCUIT Note: � When perform this adjustment, remove the Mechanism assembly. 3.6.1 Timer clock
Signal Mode Equipment (A) (B) (C) � No signal � EE � Frequency counter � IC3001 pin61 � IC3001 pin24 � C3026 + and � � C3025 (TIMER CLOCK) � 1024.008 ± 0.001 Hz (976.5549 ± 0.0010 µsec)
Measuring point (D)
(1) Set the sound carrier of the RF signal generator to S2. (2) Connect the adjustment tool (H) to the measuring point (D). Then connect the equipment (C) to the adjustment tool (H). (3) Adjust the Adjustment part (F) so that the distortion level of the measuring point (D) becomes the specified value (G). 3.5.9 Pilot VCO [HR-S6700KR]
Signal Mode Equipment (A) (B) (C) � No signal � Tuner � EE � Frequency counter � IC1501 pin 11 � C1510 (+) terminal � C1510 (�) terminal � VR1502 (PILOT VCO) � 210 ± 5 Hz
Measuring point (D1) Short point (D2) (D3) Adjustment part (F) Specified value (G)
Measuring point (D1) Short point (D2) (D3) Adjustment part Specified value (F) (G)
(1) Connect the frequency counter to the measuring point (D1). (2) Connect the short wire between the short point (D2) and Vcc (5V). (3) Short the leads of capacitor (D3) once in order to reset the microprocessor of the SYSCON. (4) Disconnect the short wire between the short point (D2) and Vcc then connect it again. (5) Adjust the Adjustment part (F) so that the output frequency becomes the specified value (G).
(1) Connect the short wire between the short points (D2) and (D3). (2) Connect the equipment (C) to the measuring point (D1). (3) Adjust the Adjustment part (F) so that the frequency of the measuring point (D1) becomes the specified value (G). (4) Disconnect the short wire between the short points (D2) and (D3). 3.5.10 Separation [HR-S6700KR]
Signal Mode Equipment Adjustment part Specified value Adjustment tool (A) (B) (C) (F) (G) (H) � Sweep generator output (90 dB, 1 kHz) � EE � Oscilloscope � IC1501 pin 19 � VR1501 (SEPARATION) � Minimum level � Sweeper probe (See Fig. 3-5-10a.)
Measuring point (D)
Shorter than 8 cm
Shield
C : 1000 P R : 75� Earth
Out
Shorter than 5 cm
Fig. 3-5-10a
Sweeper probe