Text excerpt from page 40 (click to view)
(Installation)
1. Install the SPACER shown in the Fig. 2-34-1. Note : Be sure to use the new SPACER packed with the new UPPER DRUM ASSY. 2. Install the UPPER DRUM ASSY shown in the Fig. 234-1. 3. Install the END RING so that the reference hole (A) of the END RING shown in the Fig. 2-34-2 will be placed in parallel with the Rear Line of the MAIN PLATE ASSY. (The reference hole (A) should be on the right when viewed from the bottom.) 4. Apply the screw-sealing agent to the hexagon screw (c) fastening the END RING shown in the Fig. 2-34-1. 5. Install the ROTOR CASE shown in the Fig. 2-34-3, matching its Holes with the three reference holes (B) of the UPPER DRUM ASSY. 6. Install the BRUSH shown in the Fig. 2-34-1. 7. Install the BRUSH SPRING shown in the Fig. 2-34-1. 8. Install the DRUM MOTOR STATOR shown in the Fig. 2-34-1. 9. Connect the LEAD CONNECTOR of the DRUM ASSY shown in the Fig. 2-34-1. 10. Perform the Item "PLAYBACK Switching Point" adjustment. 11. Perform the Item "Interchangeability Adjustment of the Mechanism". 12. Clean the DRUM ASSY with alcohol.
A END RING
Rear Line of MAIN PLATE ASSY
Fig. 2-34-2
ROTOR CASE
Fig. 2-34-3
B UPPER DRUM ASSY
Lock
2-35.CAPSTAN MOTOR
SET POSITION : Normal Remove the following part before replacing the CAPSTAN MOTOR. Refer to the corresponding item to install it. � REEL BELT (Item 2-14.)
Lock STAY PLATE WORM WHEEL
(Removal)
1. Rotate the WORM WHEEL in the Fig. 2-35-1 in the direction shown by the arrow A to release the Hooks of the BOTTOM ASSY from the Locks of the STAY PLATE. 2. Rotate the WORM WHEEL in the Fig. 2-35-2 in the direction shown by the arrow A so that the GUIDE ARM (TU) moves in the direction of arrow B and expose the three screws (a) fastening the CAPSTAN MOTOR. 3. Remove the three screws (a) fastening the CAPSTAN MOTOR shown in the Fig. 2-35-2 to remove the CAPSTAN MOTOR.