Probably it never existed a 1081 official service manual from Commodore, it's look more like a NAPCEC service manual & diagrams compilation of the 1084 series and his variants, like the nap6523, 8cm505, 1084S, 1084P and obviously the 1081. It's more complete than other scans and the quality of the scans also are far superior. It has two circuit diagrams variants of the 1081, mono and stereo versions. It doesn't include a diagram for the Philips CM8500 or CM8501, they look like the 1081 but they are slightly different.
;
Rapid, clear well done as all the scheme I downloaded from this site. Great job very functional and very useful
;
Great copy of the manual, has all information required for servicing,
HT-R330 OPERATION CHECK-2
SPEAKER PROTECT-2 (CURRENT DETECTION)
[When] 1. Exchange power transistors (Q6050 - Q6065). 2. Exchange amplifier PC board ass'y (NAAF-8523). [Procedure] <Note> No input. Do not check two or more channels at the same time. Do not connect dummy load to speaker terminals for seconds 2 or more. 1. Press and the hold down the CD button , then press the STANDBY/ON button when the unit is Power ON. " Test - _ " is displays it only for 5 seconds.
Te st - _
Blinks
2. Press the VIDEO 3 button, while the character of " Test - _ " is displayed. Unit will be in the state of " Test-4-00 ".
Te st - 4-00
3. Repeatedly press TONE+ button until the character of " Test-4-35 " is displayed.
Te st - 4-35
4. Connect the Dummy load of 3 ohms to the Front Lch speakers terminal. At this time, check the speaker relay is not turned off.
Te st - 4-35
5. Connect the dummy load of 1 ohm to the Front Lch speakers terminal. At that time, you check the speaker relay is turned off and " Protect " is displayed.
P rotect
Disconnect the dummy load at once when check the display of " Protect ".
Te st - 4-35
6. Check other channels according to the same procedure. 7. Press the STANDBY/ON button.