|
Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
Very helpful and complete manual. Maybe only one negative is schematics have sometimes unreadable name of the parts. But it's not a big problem.
 ;
Excellent high quality schematics brought my old Heidelberg back to life. Fast download at a reasonable price. Thanks.
 ;
This document is just what I was looking for, it´s very useful, it contains adjustment procedures for the final stage of the power amp and also
has a complete wiring diagram and description of the main semiconductors used in the design.
 ;
Dear Sirs,
Thank you for the fast support, the manual does provide all necessary information to repair the radio. All schematics are in a good quality for reading.
The manual fits 100% to my requirements as a technican.
Kind regards Thomas
 ;
the big video recorder format s-vhs many features delicate in loading system of the cassette. Such machines are no longer manufactured, it would be too expensive.
KDF-55WF655/60WF655
Clearing the Result Display To clear the result display to �0�, press the buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below: 1. If the screen is already displayed, proceed to step 3. If not, Power off (Set to Standby model). 2. Press Display Channel 5 Sound Volume Power ON 3. Press Channel 8 ENTER
Clearing the Self-Diagnostic Screen The self diagnosis screen display is cleared by turning off the set using the Remote Commander or the power switch. Self-Diagnostic Circuit Self-Diagnosis Function Operation 3 4 4 : : : Lamp cover Fan Temp The rib at the back of the lamp cover closes the SW on the T board to ground pin 3 of CN8001. It is monitored by the DE-micro (pin 94 of IC6902) and turns off the lamp when it is opened. Fan rotation is detected by "FAN-PROT" and the DE-micro (pin 92 of IC6902) turns off the lamp when it is "high". When the temperature sensor on the H3 board (WE models) or H4 board (WF/XS models) detects high temperature, or IIC-E line connector (CN6022:G2 board, CN44:H3board/H4board) is not seated securely, the DE-micro turns off the lamp. When the "LAMP-PROT" (pin 95) is low, the lamp is not turned on. If the "LAMP-HV-DET" (pin 96) is low at the same time, it is classified as no high voltage of the lamp driver. When no "DD 6V " is detected, pin 129 of TV-micro is low and it turns off the main power. When DC voltage is detected at the speaker or woofer outputs, pin 128 of TV-micro is low and it turns off the main power. When overvoltage of "+3.3V" or "+2.5V" is detected, pin 126 of TV-micro is low and it turns off the main power. When no "Digital Module 5V" is detected, pin 127 of TV-micro is low and it turns off the main power. When the "LAMP-PROT" (pin 95) is low, the lamp is not turned on. If the "LAMP-HV-DET" (pin96) is high at the same time, it is classified as no lamp or a dead lamp.
5 6 7 8 10 LAMP
: : : : : :
Lamp driver Low B error Audio D-OVP ATSC-OVP Lamp
KDF-55WF655/60WF655
10
|
|
 |
> |
|