Having bought a pre-owned Sony FM stereo tuner through eBay, it came without any manuals. It soon became clear that to get the best from this excellent tuner I needed a decent manual because much of the operation was not intuitive to a newboy to hi fi like me. I managed to download the official Sony multi-lingual manual from Owner-Manuals.com with no problem at all - a really quick and easy service. I'm very glad I did because I found out all the operations of the tuner and was then able to not only set it up quickly but also to get much more from it that poke-and-hope trialling would ever achieve. In my book $4.99 very well spent.
Text excerpt from page 11 (click to view)
2-1-4. Y signal AD calibration of COMPONENT input.
1. Check �CP_CTRL� = 0 2. Set data as follows. <Setting data> COLOR DYNA_PICT DC_TRAN 25 0 (OFF) 0 (OFF)
8. Check that the detection value of �PW_INPUT_CB� is within the standard of the following column. <Video 3 input standard value on blue full field> Item PW_INPUT_CB Standard 225 ± 2
9. Input red full field with burst. 10. Send �READ_PW_INPUT_CR� command from ECS. 11. Check that the detection value of �PW_INPUT_CR� is within the standard of the following column. <Video 3 input standard value on blue full field> Item Standard PW_INPUT_CR 225 ± 3
3. Input 0 IRE black full field with burst in video 3 input . 4. Send �READ_PW_INPUT_Y� command from ECS. 5. Check thgat the detection value of �PW_INPUT_Y� is within the standard of the following column. <Video 3 input detection value average on 0 IRE black full field> Item PW_INPUT_Y Standard 14 ± 3
6. Input 100 IRE white full field with burst. 7. Send �ADJUST_Y_LEVEL_D1� command from ECS. The Y_LEVEL_CCP2_04 registration of the D1 range is adjusted automatic by this command. Adjustment value also is copied in the D2, D3 and D4 range. 8. Check that the detection value of �PW_INPUT_Y� is within the standard of the following column. <Video 3 input detection value average on 100 IRE white full field> Item PW_INPUT_Y Standard 200 ± 2
2-1-5. C signal AD calibration of COMPONENT input.
1. Check �CP_CTRL� = 0 2. Set data as follows. <Setting data> COLOR DYNA_PICT DC_TRAN 25 0 (OFF) 0 (OFF)
3. Input 0 IRE black full field with burst in video 3 input . 4. Send �READ_PW_INPUT_CB� command from ECS. 5. Check thgat the detection value of �PW_INPUT_CB� is within the standard of the following column. <Video(composit) input detection value average on 0 IRE black full field> Item PW_INPUT_CB Standard 128 ± 5
6. Input blue full field with burst. 7. Send �ADJUST_C_LEVEL_D1� command from ECS. The C_LEVEL_CCP2_05 registration of the D1 range is adjusted automatic by this command. The value that increased and redused offset data is copied in the D2, D3 and D4 range.