Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
 ;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
 ;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
 ;
I will definitely be back for more information when I need it.
 ;
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
INTERLOCK MECHANISM AND ADJUSTMENT
The door lock m echanism is a device which has been specially designed to com pletely elim inate m icrowave radiation when the door is opened during operation, and thus to perfectly prevent the danger resulting from the leakage of microwave.
(1) Prim ary interlock switch W hen the door is closed, the hook locks the oven door. If the door is not closed properly, the oven will not operate. W hen the door is closed, the hook pushes the button of the m icroswitch. Then the button of the primary interlock switch bring it under ON condition. (2) Secondary interlock switch and interlock m onitor switch W hen the door is closed, the hook pushes the lock lever downward. The lock lever presses the button of the interlock m onitor switch to bring it under NO condition and presses the button of the secondary interlock switch to bring it under ON condition.
ADJUSTMENT
Interlock m onitor switch W hen the door is closed, the interlock m onitor sw itch should be changed(NO condition) before other switches are closed. W hen the door is opened, the interlock m onitor sw itch should be changed(NC condition) after other switches are opened.
(3) Adjustm ent steps a) Loosen the two m ounting screws. b) Adjust interlock switch assem bly position. c) M ake sure that lock lever m oves sm oothly after adjustm ent is com pleted. d) Tighten com pletely two m ounting screws.
NOTE
M icrow ave em ission test should be perform ed after adjusting interlock m echanism . If the m icrow ave em ission exceed 4m W /cm 2 , readjust interlock m echanism .
|
|
 |
> |
|
|