KRC-208S/218,268/288,28MR
TEST MODE
1. How to enter the test mode � Reset the unit while holding the "FM" key and preset "6" key. � All indication segments go ON at the beginning of the test mode. 2. How to release the test mode � Simply reset the unit. � (NOTE) The test mode is not canceled by ACC OFF, power OFF, momentary power down or the panel off. 3. Audio adjustment � Set the volume level to -10dB (which is shown as "30" on the display). � Loudness OFF. � The BASS/TREBLE and BALANCE/FADER can be set to the full-boost/full-cut and fullfront/full-rear each by pressing the "Track UP" / "Track DOWN" keys. � Sound coordination doesn't appear for the feed.