Who's Online
There currently are 6011 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
;
I got the manual quickly after the payment was transfered (1 day). The manual was exactly what i needed and the updates via e-mail were great. Thanx!
;
I've looked for this manual all over that internet, you guys had it and to a good price. A++++
;
I've looked some time for this manual, you guys had it and to a good price. A++++
;
factory technician level - complete with board views :
( removing chassis from cabinet , only thing missing ) ;
on weekends , staff is not available so - be patient .
KRF-V5010/V6010/V7010/VR-205/206/207/255/257
CIRCUIT DESCRIPTION
FUNCTION DIODE MATRIX (X14-)
Model VR-205/255 VR-206/207 VR-209 VR-257 Function KRF-V5010 KRF-V6010/V7010 KRF-V8010 DOLBY DIGITAL X X X D503 SPEAKER A only D522 X X X TV & SAP X X D506 X
3. DESTINATION LIST OF TUNER
� TUNER
TUNER Destination type K1 1700 E1 E2 LW E3 RDS Q1 RDS BAND FM AM FM AM FM MW LW FM AM FM L FM H AM Receiving frequency range 87.5MHz~108.0MHz 530kHz~1700kHz 87.5MHz~108.0MHz 531kHz~1602kHz 87.5MHz~108.0MHz 531kHz~1602kHz 153kHz~279kHz 87.5MHz~108.0MHz 531kHz~1602kHz 65.0MHz~74.0MHz 87.5MHz~108.0MHz 531kHz~1602kHz Channel space 100kHz 10kHz 50kHz 9kHz 50kHz 9kHz 9kHz 50kHz 9kHz 10kHz 50kHz 9kHz IF +10.7MHz +450kHz +10.7MHz +450kHz +10.7MHz +450kHz +450kHz +10.7MHz +450kHz +10.7MHz +10.7MHz +450kHz PLL reference frequency 25kHz 10kHz 25kHz 9kHz 25kHz 9kHz 9kHz 25kHz 9kHz 5kHz 5kHz 9kHz Diode SW DSW3 DSW2 DSW1 DSW0 D507 D505 D504 D510 0 0 0 0 0 1 0 1 0 0 1 0
K, P, R Y, M, I, C, V, E, X, H T
E Q
0 1
1 0
0 1
1 1
0 : NONE DIODE, 1: ADD DIODE
3-1 Channel Space Selector in Broadcasting setting
1. Push the BAND key for 2 seconds in the standby mode. 2. Display shows "F100/A10kHz" or "F50/A9kHz" blinkingly for 5 seconds. 3. Turn the VOLUME knob (Encoder) to choose your channel space. 4. Push the BAND key to memorize the channel space to E2P ROM. Note : Channel space will be set by the data from E2P ROM if reconnect the power cord.. Channel space will be set by the destination data from E2P ROM if backup data damaged.
3 E2P ROM check (E, T, Q, M, V type) Check the reading data and the writing data of the E2P ROM after setting the test mode. Display shows blank if the reading and writing data is the same. Display shows "&" if the different. Data (FM 50kHz, AM 9kHz, De-emphasis 50us) will be written to E2P ROM if the unit for M and V type.
4-4 ACTIVE CONTENTS
1 The mute control is not activated when the mode is switched. 2 The test mode will be terminated by plugging it off the power source or by initializing it, when all the settings will be initialized. 3 During the test mode, it can be operated in a special manner that is different from an ordinary operation by using the keys on the remote control or the main body, specifically as shown in the following table (5. contents). 4 Channel space will be no change if set channel space in the reset mode.
4. TEST MODE
4-1 SETTING
Turn the power ON while pressing the [BAND] key.
4-2 CANCEL
Unplug the AC power cord from an AC power wall outlet.
4-3 STARTING ACTIVE CONTENTS
1 The power on state is entered whenever the power is turned on while pressing the [BAND] key. All functions are then initialized and activated in the all-lighting mode. 3 All lighting mode is canceled when any main unit's keys are pressed. The normal display obtained when the selector is set to TUNER then appears.
4-5 CONTENTS
TUNER (E, T, Q, RDS ONLY)
OPERATION KEY PTY DISPLAY BASS BOOST FUNCTION � S LEVEL � RF ATT FL DISPLAY Remarks (EXP.) (1) (1) (S LEVEL), (RF ATT) OFF (2) (S LEVEL), (RF ATT) ON (2) (3) (3) (NORMAL), (RF) ATT OFF CYCLIC
P. CALL UP P. CALL FREQUENCY P. CALL DOWN
9
|
|
|
> |
|