Who's Online
There currently are 5868 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Thank´s for your help, I already recived these manual from you
;
Thank you for your manual It has the basic things to and i use the Oszi for Longer Time.
THX
;
Actually, I was looking for this information for 3 years!...now thanks to you, the manual is on my hands and of great help, cause I understand now where I was doing wrong connections and wires...excellent, I'll be back to you if in need, thank you.
;
This manual covers the main equipment features only. While it also includes the procedure for saving and loading from the now long obsolete memory cards it does not mention the how to operate with the optional floppy drive interface so I am still at a loss about how to use this! Note that there is a separate manual covering the MIDI interface and programming via the keyboard, not included in this download. You will also need to get hold of this if you want to use the MIDI interface properly. Basically there is little difference between this manual and the free to download manual for the similar PR60 model.
;
Good list of manuals. I found a very rare one and easily get. Should be promptly to download, as we must to wait hours even after confirmed payment.
KV-27V40 / 27V45 / 27V65 / 29VL40 / 29VL65A / 29VL65C / 29VL85 / 29VL95
3-2. CONVERGENCE
Preparation:
If the blue dot does not converge with red and green dots, perform the following steps: � Move BMC magnet (a) to correct insufficient H. Static convergence. � Rotate BMC magnet (b) to correct insufficient V. Static convergence. In either case, repeat Beam Landing Adjustment.
� � �
Before starting, perform FOCUS, V. LIN and V. SIZE adjustments. Set BRIGHTNESS control to minimum. Feed in dot pattern.
(1) Vertical Static Convergence
BMC magnet
V. STAT magnet
Fig. 6
Fig. 5
1.
Adjust V. STAT magnet to converge red, green and blue dots in the center of the screen. (Vertical movement) Tilt the V. STAT magnet and adjust static convergence to open or close the V. STAT magnet.
Fig. 7
( 2 ) Dynamic Convergence Adjustment
Preparation:
� 1. 2. When the V. STAT magnet is moved in the direction of arrow a and b, red, green, and blue dots move as shown below: 2. 3. 4. 5.
Before starting, perform Horizontal and Vertical Static Convergence Adjustment. Slightly loosen deflection yoke screw. Remove deflection yoke spacers. Move the deflection yoke for best convergence as shown below. ( Fig. 8) Tighten the deflection yoke screw. Install the deflection yoke spacers.
Fig. 8
� 25 �