Who's Online
There currently are 5620 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
complete part-lists and pcb layout, schematic diagram is good enlargable,
;
Excellent, fast delivery, excellent product. Good luck!
;
This manual is for the usa model only. But it is clear
, accurate and comprehensive, including board layouts and schematics.
I found it extremely useful for my mitsubishi dp-86da, but the same diagram would also work for the realistic lab5000 and hi fi 80. Thanks.
;
Great to have extra resources for Service Manuals, Now days you can really not trouble shoot efficiently without one , Wayne at IRIONS TV & ELECTRONICS REPAIR Clearwater , Fl. 33755 727-446-7955
;
For five bucks you can barely buy a hamburger. Or for the same five bucks you can buy a service manual. Much more useful. (and better for your health, depending on where you buy your hamburgers).
Yes, there are free manual sites out there, but if they don't have what you want, you have to pay.
And five bucks isn't much. Not for full specs, schematics and adjustment and parts replacement procedures.
My only criticism is that grayscale illustrations aren't well rendered, but I've seen worse.
Schematics and text are clear.
I'll be happy to purchase from here again.
Mike
[email protected]
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
1-4. PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove the anode cap. Short between anode and CRT coated earth ground strap. 7 10 8 6 3 5 4 3 1. Discharge the anode of the CRT and remove the anode cap. 2. Unplug all interconnecting leads from the de�ection yoke, neck assembly, degaussing coils and CRT grounding strap. 3. 4. 5. 6. 7. Remove the CH Board from the CRT. Remove the chassis assembly. Loosen the neck assembly �xing screw and remove. Loosen the de�ection yoke �xing screw and remove. Place the set with the CRT face down on a cushion
Coated Earth Ground Strap
1
2
9
4
and remove the degaussing coil holders. 8. Remove the degaussing coils. 9. Remove the CRT grounding strap and spring tension devices. 10. Unscrew the four CRT �xing screws [located on each CRT corner] and remove the CRT [Take care not to handle the CRT by the neck].
ANODE CAP REMOVAL PROCEDURE
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove the anode cap. After removing the anode cap, short circuit to either the metal chassis, CRT shield, or carbon painted on the CRT. NOTE: After removing the anode cap, short circuit the anode of the picture tube and the anode cap to either the metal chassis, CRT shield or carbon painted on the CRT.
REMOVAL PROCEDURES
c
a
b
Anode Button
Turn up one side of the rubber cap in the direction indicated by arrow a .
Use your thumb to pull the rubber cap �rmly in the direction indicated by arrow b .
HOW TO HANDLE AN ANODE CAP
1. Do not use sharp objects which may cause damage to the surface of the anode cap. 2. To avoid damaging the anode cap, do not squeeze the rubber covering too hard. A material �tting called a shatter-hook terminal is built into the rubber. 3. Do not force turn the foot of the rubber cover. This may cause the shatter-hook terminal to protrude and damage the rubber.
When one side of the rubber cap separates from the anode button, the anode cap can be removed by turning the rubber cap and pulling it in the direction of arrow c .