CHAPTER 3
b. Thermoswitch 1) Remove the wire cover. 2) Remove the 4 screws and then the lead wire and the thermoswitch.
�
c. Thermistor 1) Remove the wire cover. 2) Disconnect the connector and remove the cable from the fixing left cover.
� � � Screws � Thermoswitch � Connector
Figure 3-6-8 Figure 3-6-7 3) Remove the screw and the thermistor.
�
� � Screw � Thermistor
Figure 3-6-9 <Note on reassembly> When installing the thermistor, ensure that its detection surface is uniformly contacting the fixing upper roller surface. If it is not making an uniform contact, check that the plate spring has not deformed.
3 - 26
|