n
Press the key to increase the dwell time. Dwell times may be programmed from SKIP to 9 seconds. (When you reach 9 seconds, pressing the key will toggle you through the sequence again. A setting of "SKIP" removes the channel from the sequence. Select EXIT and press the
5.5.2 Alarm Dwell Time The ALARM DWELL function allows you to set the automatic reset period after an alarm is generated.
n
Select ALARM DWELL and press the following menu is displayed:
AUTO RESET TIME
key. The
n
>
key to exit the menu.
5.5 Alarm Setup The ALARM SETUP menu allows you to set the alarm options for each of the video inputs. The alarms can be set on or off, dwell time, polarity and video loss. The unit can also have the audio beeper set to on or off.
n
Select ALARM SETUP and press the following menu is displayed:
ALARM SETUP (1) (2) (3) (4) ALARM ON/OFF ALARM DWELL ALARM POLARITY VIDEO LOSS ALERT
(5) BEEPER ON (6) EXIT
5.5.1 Setup an Alarm Channel You can switch the alarm function ON/OFF for each of the four video input channels.
n
Select ALARM ON/OFF and press the following menu is displayed:
ALARM ON/OFF (1) (2) (3) (4) (5) CHANNEL CHANNEL CHANNEL CHANNEL EXIT 1: 2: 3: 4: ON ON OFF ON
key. The
n
Select ALARM POLARITY and press the following menu is displayed:
ALARM POLARITY (1) CHANNEL 1: NO (2) CHANNEL 2: NO (3) CHANNEL 3: NO (4) CHANNEL 4: NO (5) EXIT
>
>
60 SEC
key. The
> >
n
Press the and keys to adjust the time. Options are: 1-60 SEC: automatic reset period. HOLD: alarm continues until the alarm camera key is pressed followed by the ALM ( ) key. FOLLOW: alarm continues until the alarm camera key is pressed followed by the ALM ( ) key.
n
Press the
key to exit the menu.
5.5.3 Alarm Polarity The ALARM POLARITY function enables you to define how the alarm is generated for each alarm input, either normally open (NO) or normally closed (NC) contacts. key. The
n
Press the channel. Press the
and
keys to move the cursor to required
n
Press the channel. Press the
and
keys to move the cursor to required
n
key to toggle the channel ON or OFF. key to exit the menu.
n
key to toggle the channel NO or NC. key to exit the menu.
n
Select EXIT and press the
n
Select EXIT and press the
Note: Alarm functions are disabled when in the menu or VCR mode.