|
Who's Online
There currently are 5564 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Excellent service manual includes everything is need to repair this radio-caseete, how to disassemble, wiring diagram, all , waiting time until the download was only a few hours. I'm going to buy service manuals from here, are cheap and very good.Thank you.
;
Good service manual,i saved from scrapping this deck,is now fully functional.Thanks.
;
Found this to be the manual included with the original packinging, was helpfull but did not give any detailed repair instructions.
;
Complete service manual, was very helpful in repairing this tapedeck.Thanks.
;
The service manual was a copy of the original from Wirlpool. The quality was good, all neccecary information was available including the service-codenumbers, so I could order the right part to be replaced for repair.
Downloding was no probem after the payment.
Thanks for the service!
XDV-M8106ZT,M8106ZT-91
9. Operation check Terminate the test mode. Place the mechanism unit horizontally (set the main unit to the drop side). At this time, take care of short-circuiting of the PCB. 10. Check the height of the stage. Press the DISC ± key to select DISC 4. Check that the stopper bend of the clamping lever is fitted in the groove of the frame stopper section. (Fig. 3 to 5) � Precautions � The stopper bend to be clamped finally is clamped under the groove. Check the stopper bend at the position where it is fitted in the groove. � Adjustment is completed if the stopper bend enters the center and is clamped under the groove. Go to 14). � If the stopper bend is dislocated, check misalignment. Go to 11). 11. If the mechanism unit is dislocated: Place the mechanism unit facedown. When the mechanism unit is dislocated to the direction of the first disc, turn VR302 counterclockwise. (Fig. 3) Drop the voltage of EREF by 20 mV which was adjusted in 7. to descend the stage to the direction of the sixth disc by 0.1 mm. When the mechanism unit is dislocated to the direction of the sixth disc, turn VR302 clockwise. (Fig. 5) Raise the voltage of EREF by 20 mV which was adjusted in 7. to ascend the stage to the direction of the first disc by 0.1 mm. 12. Place the mechanism unit horizontally and recheck from 10. 13. After adjustment has been completed, 14. Press the EJECT switch. 15. After the operation of the mechanism unit has stopped, turn off the power. 16. After the power has be turned off, turn on the power in one minute or more and insert the magazine. 17. Check that the mechanism unit operates normally for the first and fourth discs. 18. Terminate all adjustment for OK (normal operation) and readjust for NG (abnormal operation).
EREF
GND
VR302
47k�
L.P.F.
1µF
Oscilloscope
67
|
|
|
> |
|