Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
Good quality service manual German user manual. German user manual This is a quality scan of a manual in excellent condition and is just as good as having the original manual in hand
 ;
The manual for Sony LBT-D505 component stereo system is was excellent , with schematics, parts layout and parts list as well as instructions for adjustments for each component. Print was clear even when enlarged.
 ;
It's exactly a complete and very useful manual with all details what I needed. Thank you!I will come back whenever I need your manuals or schematics.
 ;
I searched EVERYWHERE looking for the manual/s on this "extinct" amp. Owner-Manuals.com made it available and for nearly nothing. Thanx to them, I can decipher the unknown cables and sort them out. Thanx, Owner-Manuals.com!!
 ;
Yes thank you i got the file i was after. There was a slight problem in my communication but it all worked out well.
A job well done.
M-640V/645V/647V SECTION 3 MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback/erase head pinch roller rubber belts capstan 2. Demagnetize the record/playback/erase head with a head demagnetizer. 3. Do not use a magnetized screwdriver for the adjustments. 4. The adjustments should be performed with the rated power supply voltage unless otherwise noted. Power supply voltage: 3 Vdc TAPE SPEED switch : 2.4 cm Torque Measurement
Mode Forward Fast Forward Torque Meter CQ-103M CQ-201M Meter Reading 0.49 � 1.27 mN � m (5 � 13 g � cm) (0.07 � 0.180 oz � inch) more than 2.95 mN � m (more than 30 g � cm) (more than 0.42 oz � inch) Rewind CQ-201M more than 2.95 mN � m (more than 30 g � cm) (more than 0.42 oz � inch)
SECTION 4 ELECTRICAL ADJUSTMENTS
Specified voltage: 3 V (DC) Test Tape
Type S-2-A030 WS-24 WS-12 Signal 3 kHz, � 20 dB 3 kHz, � 10 dB Used for Head Azimuth Adjustment Tape Speed Adjustment Tape Speed (cm/s) 2.4 2.4 1.2
Record/Playback/Erase Head Azimuth Adjustment
Setting: [VOL] control : mechanical mid [TAPE SPEED] switch : 2.4 cm/s [VOR] switch : OFF Procedure: 1. Mode: Playback
test tape S-2-A030 (3 kHz, �20 dB) set
level meter 16 � + �
Tape Tension Measurement
Mode Forward Tension Meter CQ-403M Meter Reading more than 20 g (more than 0.28 oz)
[EAR] jack (J101)
2. Turn the head azimuth adjustment screw to obtain the maximum reading on level meter.
Note: Several peaks may appear, but the maximum.
Adjustment Location: First remove the cover (AZ).
Remove the cover (AZ).
head azimuth adjustment screw