Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
Very good scanning quality. All schematics are very legible. Worth every cent !
Text excerpt from page 4 (click to view)
Alignment and Adjustments
1-2 Cassette Deck
1-2-1 To Adjust Tape Speed
Notes * Measuring tape: i) MTT-111 (or equivalent) (Tapes recorded with 3kHz) ii) MTT-5512 (or equivalent)
- Adjust SPEED Control Step Item SPEED Control Tape MTT-111N (3KHZ) PreSetup
Press play button after puting tape into the Deck1
Adjust Point
UVR2(COMMON) DVR3(Only MAX909/910/916)
Standard 3 kHZ ±1% 3 kHZ ±1%
Figure Fig. 1-5 Fig. 1-5
Remark
Front PCB Main PCB
5200~6600Hz Check
1
2
HI SPEED Control
MTT-111 (3KHZ)
No Adjustment
-
Fig. 1-5
- Adjust Record Frequency Step 1 Item L,R Unbalance Record Frequency Tape MTT-112B (1KHZ) MTT-5512
Press Rec button after connecting (Fig1-6)
PreSetup
Adjust Point DVR4
Frequency Range ±0.5dB
60KHZ±1KHZ (Only MAX909/910/916) 85KHZ±1KHZ(COMMON)
Figure Fig. 1-6
Remark SPEAKER VTVM (A-DECK) DCW4
2
DL4
Fig. 1-6
- Adjust Azimuth Step Item Tape PreSetup Adjust Point Adjustment screw of HEAD Standard Figure Remark
1
Azimuth
MTT-113CN
8KHZ
Fig. 1-7
Output:Maximum
- Adjust Rec Bias Voltage Step Item Rec Bias Voltage Tape MTT-5512 (3KHZ) PreSetup Adjust Point SVR1 SVR2 Votage Range 7V±0.5V Remark Connect to MWF6 from AC Meter.
1
Fig1-8. Adjustment location of Deck Part