This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
HCD-CPX22/NXM3
[GC � � � �
Test Mode] All fluorecent segments and LEDs are tested. Microprocessor virsion. Keyboard check. Display check.
[MC Test Mode] (Tape section) � This mode is used to test the functions of the Tape Procedure. Procedure: 1. Press ?/1 button to turn the set ON. 2. To enter the test mode, press the three buttons x , X and z/START simultaneously. 3. While holding the [DIMMER] button depressed, turn the ALC ON. 4. Press the z/START button to start REC (recording). 5. While recording, press the [TUNING +] button to perform automatic rewind and automatic playback (for FF version). Also, press the [TUNING -] button to perform automatic rewind and automatic playback (for FR version). 6. Select the function �TAPE A� or �TAPE B� 7. Press the [CD-SYNC] button while �TAPE A� or �TAPE B� is selected, to perform AMS check. �EDG[ ]� is displayed. A number appears inside[ ]. 8. To exit from this mode, press ?/1 button to turn the set OFF. [CD Ship Mode (LOCK) ] � This mode moves the pick-up to the position durable to vibration. Use this mode when returning the set to the customer after repair. Procedure: Press ?/1 button to turn the set ON. Select the function �CD�. Press x button and [CD] button simultaneously. The �STANDBY� display blinks instantaneously, and the CD ship mode is set. 5. To fluorescent indicator tube displays ��LOCK��. [CD Ship (LOCK) & COLD RESET MODE] Procedure: 1. Press ?/1 button to turn the set ON. 2. Select the function �CD�. 3. Press three buttons x , X and VIDEO (MD) simultaneously. 4. The �STANDBY� display blinks instantaneously and CD ship mode is set. 5. To fluorescent indicator tube displays �LOCK� and the set is reset. [CD power -manage function] Procedure: 1. Press ?/1 button to the set ON 2. Select the function �CD�. 3. Press ?/1 button to turn the set OFF. 4. Press x and ?/1 buttons simultaneously ,and the display of fluorescent indicator tube changes �CD POWER OFF� or �CD POWER ON�. 5. Press ?/1 button to turn the set OFF. 1. 2. 3. 4.
Procedure: 1. To enter the test mode, press the three buttons x , X and [TUNER/BAND] simultaneously. 2. All segments and LEDs (without STANDBY LED) are turned on. 3. Press the [TUNING -] button to increment the microprocessor software version. 4. Press the [TUNING +] button to change the indication for the microprocessor software version. 3. Press the b B button to set the check mode for the entries (KEY, JOG, etc.). 4. Press the X button to display the current VACS level. 7. Press the x button to enter the mode to check the display. If you press this button repeatedly, the display will change sequentially as the button is pressed. 8. Press the x , X and [TUNER/BAND] buttons simultaneously to set the standby mode. [CD Service Mode] � This mode can run the CD sled motor freely. Use this mode, for instance, when cleaning the pick-up. Procedure: 1. Press ?/1 button to turn the set ON. 2. Select the function �CD�. 3. To enter the test mode, press three buttons x , X , and [DISC 1] simultaneously. 4. The CD service mode is selected.The message ��CD SERVICE MODE�� is displayed. 5. While holding the [TUNING -] button depressed , to move the sled to the inside. �SLED IN� is displayed. While holding the [TUNING +] button depressed, to move the sled to the outside. �SLED OUT� is displayed. 6. Press the [CD SYNC] button so that �LD ON� and �LD OFF� are displayed to switch between Laser ON/OFF. 7. To exit from this mode, perform as follows: 1) Move the pick-up to the most inside track. 2) Press ?/1 button to turn the set OFF.
Note: � Always move the pick-up to most inside track when exiting from this mode. Otherwise, a disc will not be unloaded. � Do not run the sled motor excessively, otherwise the gear can be chipped.
[MC Test Mode] (Amplifier SECTION) � This mode is used to test the function of the amplifier section. Procedure: 1. Press ?/1 button to turn the set ON. 2. To enter the test mode, press the three buttons x , X and 3. 4. 5. z/START simultaneously. Turn [VOLUME] knob to counter-clockwise, the function of the equalizer is set to �MIN�. Turn [VOLUME] knob to clockwise, the function of the equalizer is set to �MAX�. Whenever turn [BASS] knob to clockwise, the display switches as follows. �TONE MAX� t�TONE MIN� t�TONE FLAT� To exit from this mode, press ?/1 button to turn the set OFF.
6.
15
|
|
|
> |
|