Even if the PDF is a scan, I can read the information I need.
The price is affordable and the service (mail sending) is very fast.
Thanks ! Regards. William (Fan of Kenwood)
Text excerpt from page 16 (click to view)
HCD-DX10/RG4SR/RG20/RG30T
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. RF Level Check
oscilloscope CD board IC751 pin q; GND
Procedure : 1. Connect oscilloscope to pin q; (IC751). 2. Turned Power switch on. 3. Load a disc (YEDS-18) and playback. 4. Confirm that oscilloscope waveform is clear and check RF signal level is correct or not.
Note : Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
level : 1.4 to 2.1 Vp-p
Adjustment Location: CD board [CD BOARD] (Component Side)
CN732