Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
;
We received the manual in a timely manner and it was exactly what we were expecting.
;
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
;
Very good scanning quality. All schematics are very legible. Worth every cent !
;
Excellent quality, very quick download turnaround, will definately use again.
CDP-S3 SECTION 5 ELECTRICAL ADJUSTMENTS
Note :
E-F Balance (1 Track jump) Check
oscilloscope BD board TP(TEO) TP(DVC)
1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use LUV-P01 (4-999-032-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. S-Curve Check
BD board TP(FEO) TP(DVC) Oscilloscope
Procedure : 1. Connect an oscilloscope to TP (TEO) and TP (DVC). 2. Turn Power switch on. 3. Load a disc (LUV-P01) and playback the number nine track. 4. Press the N button. (Becomes the 1 track jump mode.) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
1 track jump waveform center of waveform B DVC level=1.0 ±0.5Vp-p symmetry A (DC voltage)
Procedure : 1. Connect an oscilloscope to TP (FEO). 2. Connect between TP (FEI) and TP (DVC) ( 1.65 V) by lead wire. 3. Turn Power switch on. 4. Load a disc (LUV-P01) and actuate the focus search. (In consequence of open and close the disc tray, actuate the focus search) 5. Confirm that the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 2 ± 0.5 Vp-p.
S-curve waveform symmetry
6. Adjust RV101 on the BD board so that the center of waveform becomes the same voltage of DVC. (i.e. A=0V) Adjustment Location: [BD BOARD] (Conductor Side)
A within 2 ±0.5Vp-p B
6. After check, remove the lead wire connected in step 2.
Note : � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform.
RF Level Check
BD board TP(RFDC) TP(RFAC) TP(DVC) oscilloscope
TP (DVC) TP (RFAC) 15 1 IC103 16 30 TP (FEO) TP (TEO) 40 41 TP (RFDC)
21 20
TP (FEI)
IC101 60 61
1 80
Procedure : 1. Connect an oscilloscope CH1 to TP (RFDC) and CH2 to TP (RFAC). 2. Turn Power switch on. 3. Load a disc (LUV-P01) and playback. 4. Confirm that oscilloscope waveform is clear and check if RF signal level is correct or not.
Note : Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RV101
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
level : 0.65 ±0.15Vp-p (RFDC) 1.1 ±0.4Vp-p (RFAC)