some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
;
I will definitely be back for more information when I need it.
;
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
;
The manual is useful for trouble shooting for an old instrument. It saved money,and let me enjoy DIY.
d. Fitting the Grid Wire for the Primary Corona Unit 1 ) Loosen the three screws holding the block (front) in place, move the block (front) into the direction of the arrow shown in Figure 4-509, and tighten it temporarily.
Free a length of wire from the reel of the corona wire (O.lmm dia.), and form a loop with a diameter of 2 mm at its end. 3) Cut the end of the twisted corona wire [excess) to less than 1 mm with a nippier. 4) Hook the loop on the stud shown in Figure 4-5 10, and fit it in the order shown in the figure. 5) After (Figure 4-5 lo), wind the end of the corona wire around the fixing screw to fix it in place. 6) Cut the excess wire to less than 1 mm with a nipper. 7) Loosen the screw tightened temporarily in step 1) once again, and move the block into the opposite direction of the arrow shown in Figure 4-509, and adjust the tension of the grid wire. 9) Wipe the grid wire with a dry cloth. 9) Check the tcllowrng: . The grid wire is free of bends or twists and its gold plating has not peeled. . The wire is fitted at equal intervals, i.e., the grid wire is inside the groove of the bloc-k.
2)
@ Mounting
screws Figure 4-509
Note: To form the loop, wind the corona wire around the hex key once, and turn the hex key three to four times; thereafter, twist the corona wire.
Figure
4-510
COPYAlCHT
0
1991CANONINC.
CANONNP.483514835114835S14335 AN 0 WT
1988PRlNTE9 JAPANlIMPRIME JAPONI IN AU
4 - 28
$4.99 NP4835 CANON Parts Catalog Parts Catalog only. It's available in PDF format. Useful, if Your equipment is broken and You need t…
|
|
|
> |
|