|
Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Impressively thorough. Even the simple operators manual helped me "fix" one of the 2 CD players in the unit. This unit reads CD's from the top so they should be installed in the magazines "upside down" from typical CD players. The CD player service manual helped me unjam a stuck carriage because somebody transported the box laying down loaded with CD's. A little lens cleaning & the player now works well! Thanks for you help at a great price! Joe
;
I was skeptical at first but later found the manual to be good quality for the price. It took a couple hours to receive the email with the download link, well worth the wait. Thanks.
;
very helpful, I could not have cleaned motherboard and replaced the main fan without it
;
Good manual, schematics nice and clear with good quality scanning. Woul dhave been nice to have immediate access after purchasing though.
;
I was very glad recieving the service manal from You. Manuals were delivered promptly and were correct as advertised. A complete and very usefull service manual with all details. Thank you!
PCD-001,PCD-002,PCD-003,PCD-004
1.2 SAFETY INFORMATION
IMPORTANT THIS PIONNER APPARATUS CONTAINS LASER OF CLASS 1. SERVICING OPERATION OF THE APPARATUS SHOULD BE DONE BY A SPECIALLY INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS MAXIMUM OUTPUT POWER : 5 mw WAVELENGTH : 780-785 nm
H. P. SOUND LABEL NYXTL type Only
LABEL CHECK
COMPLIES WITH FDA RADIATION PERFORMANCE STANDARDS,21 CER SUBCHAPTER J. MANUFACTURED ADT
FDA LABEL KUCXTL type Only
FCC/FDA/DOC LABEL KUCXTL type Only
WARNING LABEL NYXTL and NVXTL types
Bottom
BT CAUTION LABEL
Inside SW Laser P.U.
Additional Laser Caution SW102 (DOOR Detect SWITCH)
1. Laser Interlock Mechanism The position of the switch (SW102) for detecting the loading state is detected by the system microprocessor, and the design prevents laser diode oscillation except when both switch (SW102) is not on CLMP terminal side (CLMP signal is OFF or high level.). Thus, interlock will no longer function if switch (SW102) is deliberatery shorted (low level). The interlock also does not function in the test mode�. Laser diode oscillation will continue, if pin 36 of CXA1992A (IC102) on the CD AMP UNIT is connected to GND, or else the terminals of Q107 are shorted to each other(fault condition).
*
BATTERY
CD AMP UNIT
2. When the case is opened, close viewing of the objective lens with the naked eye will cause exposure to a Class 1 laser beam.
� Refer to page 19.
3
|
|
|
> |
|