|
Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
It is an very good and clear scanned service manual.
very recommended.
;
Easy to order the manual. Good quality and fast delivery.
;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
PCD-001,PCD-002,PCD-003,PCD-004
1.2 SAFETY INFORMATION
IMPORTANT THIS PIONNER APPARATUS CONTAINS LASER OF CLASS 1. SERVICING OPERATION OF THE APPARATUS SHOULD BE DONE BY A SPECIALLY INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS MAXIMUM OUTPUT POWER : 5 mw WAVELENGTH : 780-785 nm
H. P. SOUND LABEL NYXTL type Only
LABEL CHECK
COMPLIES WITH FDA RADIATION PERFORMANCE STANDARDS,21 CER SUBCHAPTER J. MANUFACTURED ADT
FDA LABEL KUCXTL type Only
FCC/FDA/DOC LABEL KUCXTL type Only
WARNING LABEL NYXTL and NVXTL types
Bottom
BT CAUTION LABEL
Inside SW Laser P.U.
Additional Laser Caution SW102 (DOOR Detect SWITCH)
1. Laser Interlock Mechanism The position of the switch (SW102) for detecting the loading state is detected by the system microprocessor, and the design prevents laser diode oscillation except when both switch (SW102) is not on CLMP terminal side (CLMP signal is OFF or high level.). Thus, interlock will no longer function if switch (SW102) is deliberatery shorted (low level). The interlock also does not function in the test mode�. Laser diode oscillation will continue, if pin 36 of CXA1992A (IC102) on the CD AMP UNIT is connected to GND, or else the terminals of Q107 are shorted to each other(fault condition).
*
BATTERY
CD AMP UNIT
2. When the case is opened, close viewing of the objective lens with the naked eye will cause exposure to a Class 1 laser beam.
� Refer to page 19.
3
|
|
|
> |
|