Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Quick site processing. A complete and very useful manual with all details. Thank you!
;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
;
The manual was well-scanned and easy to read. As an added bonus, the Operator's Manual was bundled with the Service Manual!
I'd definitely use owner-manuals.com again.
;
Finally, i found one website, where i can download this service manual , and fix my hifi. The service manual is very good, and easy to download and to print.
PCD-001,PCD-002,PCD-003,PCD-004
1.2 SAFETY INFORMATION
IMPORTANT THIS PIONNER APPARATUS CONTAINS LASER OF CLASS 1. SERVICING OPERATION OF THE APPARATUS SHOULD BE DONE BY A SPECIALLY INSTRUCTED PERSON.
LASER DIODE CHARACTERISTICS MAXIMUM OUTPUT POWER : 5 mw WAVELENGTH : 780-785 nm
H. P. SOUND LABEL NYXTL type Only
LABEL CHECK
COMPLIES WITH FDA RADIATION PERFORMANCE STANDARDS,21 CER SUBCHAPTER J. MANUFACTURED ADT
FDA LABEL KUCXTL type Only
FCC/FDA/DOC LABEL KUCXTL type Only
WARNING LABEL NYXTL and NVXTL types
Bottom
BT CAUTION LABEL
Inside SW Laser P.U.
Additional Laser Caution SW102 (DOOR Detect SWITCH)
1. Laser Interlock Mechanism The position of the switch (SW102) for detecting the loading state is detected by the system microprocessor, and the design prevents laser diode oscillation except when both switch (SW102) is not on CLMP terminal side (CLMP signal is OFF or high level.). Thus, interlock will no longer function if switch (SW102) is deliberatery shorted (low level). The interlock also does not function in the test mode�. Laser diode oscillation will continue, if pin 36 of CXA1992A (IC102) on the CD AMP UNIT is connected to GND, or else the terminals of Q107 are shorted to each other(fault condition).
*
BATTERY
CD AMP UNIT
2. When the case is opened, close viewing of the objective lens with the naked eye will cause exposure to a Class 1 laser beam.
� Refer to page 19.