Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs.
Manual is old and was not produced in PDF- scanned copy is exellent.
Overall- value for money- I recommend
;
Excellent quality and quickly delivered manuals at a fair price. Great care is taken in the reproduction process. Even photographs and highly detailed drawings are as clear as in the original. That cannot be said for some freelance manual copies I have obtained from the web. If you have exhausted your internet search of technical manuals, try Owner-Manuals.com. If they do not have it, I do not think it exists. Perhaps, if requested, they may be able to find it. Their resources are certainly greater than most. Shopping here certainly beats waiting for months or years for the manual you seek to appear in an internet auction or garage sale.
;
Very detailed product, also it is a scanning from original, very useful if you have to service this type of amplifier ! Very good product, very hard to find!
;
the Manual was made available as promised, the scans were excellent..Good Work !!!
4-1. Check Items Before Starting Self-diagnostics
3. When the DE-55 board is suspected to be defective . Select an oscilloscope setup of 20 MHz with band-width limit: OFF. . Adjust the brightness of the incoming light until 400 mVp-p is obtained at TP401 and TP402. . The circuit stage up to TP141 must be diagnosed by observing the waveform of the carrier signal and by checking the operating condition with no input signal fed to the infrared transmitter. The circuit stages after that must be diagnosed by observing the demodulated waveform and by checking the operating condition with the color bar signal being input to the infrared transmitter. a) Check that the DC voltages that are supplied from the power supply to the respective blocks are correct or not. � When the DC voltages are normal, the voltages from MA-107/107P board are; TP491: 5 ± 0.5 V, TP391: 9 ± 0.5 V. � When DC voltages are abnormal; Soldering of CN101 is suspected to be defective, or flexible flat cable (FFC) has poor connection or is broken. b) Check DC voltage at L491 and check the signal flow from TP401 to TP404. [RF amplifier] � When the circuit is normal, the waveforms [No. 1 to No. 5] that are shown on page 4-21 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block of Ref. 400 to Ref. 409. Replace the transistor as needed. c) Check DC voltage at L492 and check the signal flow from TP421 to TP424. [RF amplifier] � When the circuit is normal, the waveforms [No. 1 to No. 5] that are shown on page 4-21 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; in the circuit block of Ref. 420 to Ref. 439. Replace the transistor as needed. d) Check DC voltage at L491. [ANALOG_5.9 V] � When the circuit is normal; 5.9 ± 0.5 V � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block in which abnormality has occurred. Replace the transistor Q901 or others as needed. e) Check Q110 for correct operation by observing the output waveform at TP101. [BUFFER] � When the circuit is normal, the waveform [No. 6] that is shown on page 4-21 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block in which abnormality has occurred. Replace the transistor Q110 or others as needed. f) Check IC101 for correct operation by observing the output waveform at TP102. [LIMITTER] � When the circuit is normal, the waveform [No. 7] that is shown on page 4-22 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block in which abnormality has occurred. Replace IC101 or others as needed.
4-18