Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 6043 guests online.
Categories
Information
Featured Product
Home >> PIONEER >> PDP-6010FD/KUCXC Service Manual
 
 0 item(s) in your cart 

PIONEER PDP-6010FD/KUCXC
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of PIONEER PDP-6010FD/KUCXC Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 SX-PR307 TECHNICS Service Manual by Alexander McLeay;
Downloaded the Service manual OK of the Technics Piano and have now repaired it and its going fine. Excellant; thank you for the fine servce. A.M
 SX-EX25L TECHNICS Service Manual by Odd Pettersen;
This site is working fine! Did buy a manual for SX-EX25L and after a while I could download it and fix the problem. Nice and easy!
 B25EMOTION REVOX Service Manual by Georg Schuppien;
Complete manual as pdf-file in very good quality. Very helpful and fast availability.
 HP 3700 ROLAND Service Manual by Axel Schaab;
Complete service manual in very good scanning quality with all schematic and PWB graphics as well as assembly & maintenance instructions. A slight drawback is that the rastering of the PWB graphics sometimes makes it a bit difficult to follow fine traces, but no showstopper.
 KM-3000 JVC Service Manual by Johannes Zündel;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site. Thank you very much

Text excerpt from page 47 (click to view)
5

6

7

8

5.2.2 POWER SUPPLY UNIT

Flowchart of Failure Analysis for The POWER SUPPLY Unit
Failure analysis for the POWER SUPPLY Unit => PS1 STB 3.3 V power is not output.

A

Is the cable connected firmly to the P4 connector? Yes Is the cable to the P4 connector broken? No Is the cable connected firmly to the P9 connector? Yes Is the cable to the P9 connector broken? No Is the fuse (F001) blown? No Is one of the limiting resistors (R001/FR001) blown? No The POWER SUPPLY Unit is normal.

No

Properly connect the cable between the P4 and D23 connectors.

Yes Replace the defective cable (J104).

Check the voltage at the DIGITAL Assy and POWER SUPPLY Unit.

B

No

Properly connect the cable between the P9 and M2 connectors.

Yes

Replace the defective cable (J106).

Yes Replace the POWER SUPPLY Unit.

Yes Replace the POWER SUPPLY Unit.

Check the resistance between F001 and the D002 anode, using a tester.

C

Failure analysis for the POWER SUPPLY Unit => PS2

The power is not on, even though the RELAY port is active.

No Is the relay (RL002) on? Yes No Is the PFC voltage normal? Yes The POWER SUPPLY Unit is normal.

Replace the POWER SUPPLY Unit.

� Check the relay operation at the terminal (Pin 11 of P4). (Voltage: 3.3 V) � Check the relay sound (click).

D

Replace the POWER SUPPLY Unit.

� Check the voltage between the F301 lead (PFC OUT) and heat sink (GND of primary side) terminal. � The voltage must be around 390 V. Caution: High voltage!

Failure analysis for the POWER SUPPLY Unit => PS3

The cells of the panel do not light normally.

Is the VADR voltage within the specified values? Yes Is there a fluctuation in the VADR voltage? No Is the VSUS voltage within the specified range? Yes Is there a fluctuation in the VSUS voltage? No The POWER SUPPLY Unit is normal.

No

Replace the POWER SUPPLY Unit.

The specified voltage values are between 57 and 63 V.

E

Yes Replace the POWER SUPPLY Unit.

The ripple must be within 5 V.

No

Replace the POWER SUPPLY Unit.

The specified voltage values are between 205 and 215 V (VSU: 125/35°C).

Yes Replace the POWER SUPPLY Unit.

The ripple must be within 10 V.

F