There are currently no product reviews.
 ;
Good pdf of the service manual for this unit. Includes disassembly instructions, full schematics, board layouts, parts lists and diagnostic information. Some information is in the pdf twice (single pages, and split pages), but that could be how it was originally generated by panasonic, or perhaps the idea is to make it eaiser to put onto 8.5 x 11" pages.
Information was exactly what I needed. Delivery was overnight (less than 12 hours) and I was happy with the process.
 ;
5 STARS for FAST DELIVERY, BEST PRICES and QUALITY PRODUCT. Item was exactly as described with superb resolution. Will definitely source all my future requirements from this website. Thanks a lot owner-manual.com!
 ;
OEM manual provided all schematics, board layouts and component specs necessary to facilitate unit maintenance. All pages were clear and readable.
 ;
Good condition and quality. Hard to find anywhere in Internet, only on this site.
 ;
Exactly what I needed to be able to bring the amp back to life... will come back to this site the next time I need schematics.
5.
Press the UP/DOWN button to select the item CONT. Then Press UP/DOWN to adjust the waveform as Fig. 2. Then press Enter button to return. Gout
2.8+/-0.1V
Fig.2 6. Setup for oscilloscope as follows. CH1: 1V/div => TL45(Gout), CH2: 1V/div => TL44(Rout), Time: 10us/div, Trigger: TL1(VCOM), Falling Edge. Press the UP/DOWN button to select the item SBRTR. Then Press UP/DOWN to adjust the waveform as Fig. 3. Then press Enter button to return. Rout, Gout or Bout, Gout
7.
Fig.3 8. Setup for oscilloscope as follows. CH1: 1V/div => TL45(Gout), CH2: 1V/div => TL46(Bout), Time: 10us/div, Trigger: TL1(VCOM), Falling Edge. Press the UP/DOWN button to select the item SBRTB. Then Press UP/DOWN to adjust the waveform as Fig. 3. Then press Enter button to return. Setup for oscilloscope as follows. CH1: 1V/div ---, CH2: 1V/div => TL1(VCOM), Time: 10us/div, Trigger: TL1(VCOM), Falling Edge. Select the item VCOM. Then Press UP/DOWN to adjust the waveform as Fig.4. Adjust the voltage peak to the range of 5.6+/-0.1V. Then press Enter button to return. Press the UP/DOWN button to select the item DAC. Then to adjust the waveform is shown as fig. 4. The value is �1.7+/-0.1V. Then press Enter button to return. VCOM 5.6+/-0.1V -1.7+/-0.1V
9. 10.
11. 12.
Fig.4 13. 14. Press the UP/DOWN button to select the item H_POS. Then to set the green edge to center of LCD. Then press Enter button to return. Power off the camera after calibration. Remove the SD Card and AC Adapter cable.
13
|