|
Who's Online
There currently are 5963 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
Procedure: 1. Install the SD card with calibration code into camera. 2. Attach camera to AC adapter. The camera starts to sound �di di� and then enter the Bright Level to adjust the menu. 3. Use the test pins of multimeter to touch the camera as shown. The black pin touches to the metal frame (GND), and the red pin touches to the LCD negative soldering pad (white wire). 4. Use touch pen on touch panel to adjust the reading on multimeter is 370 +/- 5mV, then press the shutter button to save it. 5. Repeat the above step 3 to adjust the reading to 220 +/- 5mV for Normal Level. 6. Repeat the above step 3 to adjust the reading to 100 +/- 5mV for Dim Level. 7. Press shutter button to get out of the calibration status.
The position on touch panel KEY
SAVE
*
=
Shutter Button Fig 3-7
3-3 LCD Calibration Test Tools: AC Adapter SD Card with Calibration Code [lcdcal.exe] --- Self-extracting execution Oscilloscope The all test points for vector pins are on the logic board U100. The setting of scope: Setting 1: CH1---VG(the white wire as shown), 0.5V, 25.0uS; Trigger Signal: CH4---VCOM; Synchronization: scanning Setting 2: CH1---VG(the white wire as shown), 0.5V, 25.0uS; CH2---VR(the black wire as shown), 0.5V, 25.0uS; Trigger Signal: CH4---VCOM; Synchronization: scanning Make sure the waveform of CH1 and CH2 is overlap together, then switch off the CH1 and CH2. Choose MATH, �-� to get the waveform of �CH1-CH2�. Setting 3: CH1---VG(the white wire as shown), 0.5V, 25.0uS; CH2---VB(the blue wire as shown), 0.5V, 25.0uS; Trigger Signal: CH4---VCOM; Synchronization: scanning Make sure the waveform of CH1 and CH2 is overlap together, then switch off the CH1 and CH2. Choose MATH, �-� to get the waveform of �CH1-CH2�. Setting 4: CH4---VCOM(the brown wire as shown), 1.0V, 25.0uS; Trigger Signal: CH4---VCOM; Synchronization: scanning GND: the red wire as shown
11
|
|
|
> |
|