Who's Online
There currently are 5965 guests and 1 member online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
It's a grate service manuals.Have many details and the writing it's so clear.You have all you want in manual,nothing missing,belive me.I'm verry satisfied of this manual.
;
Great scanned service manual
Usefull informations.
I will buy again!
Best Regards
;
The manual describes this product very good. It has the basic things to know and also a more detailed look. Very well made!
;
An excellent document to assist in the repair of my old personal tape player. It includes full circuit diagrams and physical layout drawings and full instructions on disassembly and fault finding.
Well worth the meagre price.
;
Very good conversation, Pretty fast Service, wood do it again,
Have paid by Paypal, so i got the Service Manual online after 15 Min.
Very helpfully.
Greeting from Germany,
Hans
3-6. CONVERGENCE ADJUSTMENT
1. Input the dot pattern signal. Set CONTRAST to the position at which it can be seen clearly. Set BRIGHTNESS to MIN. 2. Align the R, G, B dots in the horizontal direction at the center of the screen using RV703 (H-STAT). Note: If H-CENT was changed after adjusting HSTAT, adjust H-STAT again. (The HSTAT can be changed by the H-CENT switch.) 3. Align the top and bottom of R, G, B at the center of the screen using the V-STAT (vertical static convergence) magnets. Note: After the V-STAT adjustment, always paint the magnets to lock.
I I' I I'
5. For VMC, use a 6-pole magnet to adjust so that the R and B dots are symmetrical above and below the G dot.
R (Top section) Fixed G B
(Bottom section)
6-pole magnet Perform the VMC adjustment by rotating the 6-pole magnet to the left and right without changing the opening of it.
Adjust so that the displacement of the dot is equal at the top and bottom.
A
B
A
B
6. Repeat steps 2 to 5 until the convergence becomes correct. Note: Adjusting the convergence may affect the landing. Therefore be sure to check the landing again after completing this adjustment. 7. After adjusting, paint each magnet to lock them.
14-inch
X
X
Y Good example
Y Bad example
V.STAT convergence magnet Purity BMC magnet
While maintaining the V-STAT magnet knobs A and B at the same angle (I = I'), adjust the top and bottom convergences. If A and B are asymmetrical (I = I'), it will have a negative effect; the focus may not be accurate, or the beam striking may occur. 4. For HMC, use a 6-pole magnet and adjust so that the R and B dots are symmetrical at the left and right sides in respect to the G dot.
I I' R G B
20-inch V.STAT convergence magnet
A
B A A'
Purity BMC magnet
6-pole magnet Perform the HMC adjustment by changing the opening of the 6-pole magnet.
Adjust the 6-pole magnet so that A = A'. While maintaining the I and I' angles equal, adjust the 6-pole magnet.
3-6