Text excerpt from page 19 (click to view)
7-3. OPERATION CHECK
q TAPE DETECTION SWITCH
Opening the cassette case cover, six black switches (TAP1~6) appear. (Refer to the right figure) These switches detect the tape width, length and coloring. In the case of short color tape, refer to the lower table. Normally, these tapes are used for QG-100.
Refer to 4. SCHEMATIC DIAGRAM (4-5. Sensor PCB Z568-2).
q OPERATION CHECK (QV camera-QV-10, QV-10A, QV-30. Don't use QV-100)
1.Make the jig for check using SB-20 or SB-62 communication cable as mentioned bellow.
§
Cut the cable, then strip the covering. Strip the covering of red and white wire, then solder these core wire. Cut the copper wires for shielding.