The service manual was very usable and clear enough to see the individual values of all of the components (unlike some of the service manuals I have gotten in the past from web sites similar to this one). The price was right and the information was greatly appreciated. It helped me with an otherwise very difficult repair. It was much needed and appreciated. A faster turn around on my order would be nice, but I understand the constraints on your staff's time. Thank you for your service.
 ;
Excellent manual. Helped me out with disassembling and troubleshooting my projector.
 ;
thanks you are the best.Very good detail, Quick service response. A useful service manual with all details.
 ;
Great service!!! Polecam gorąco wszystkim zainteresowanym
RD-M52MD/M72MD
ADJUSTMENT
CD section
NO. ITEM INPUT SETTINGS OUTPUT SETTINGS CD PLAYER SETTINGS ALIGNMENT ALIGN FOR FIG.
TEST MODE : While pressing the CD PLAY/PAUSE key ,plug the power cord into the AC power wall output. Load the TEST DISC. [1] LASER CURRENT CHECK Test disc type 4 Connect the DC voltmeter between 3 and 4 of CN4 on X29. Connect an oscilloscope as follows. CH1:RF(X29, CN4, 1) GND:VC(X29, CN4, 2) Connect an oscilloscope as follows. CH1:RF(X29, CN4, 1) GND:VC(X29, CN4, 2) Note: � Type 4disc: SONY YEDS -18 Test Disc or equivalent. � Keep the step of adjustment. Press the PLAY/PAUSE key to check that the display is 03 or05. 50±20mA
[2]
FOCUS ERROR BIAS (Set up vertically) FOCUS ERROR BIAS (Set up horizontally)
Test disc type 4
Press the PLAY/PAUSE key . Confirm that the display is 05. Press the PLAY/PAUSE key . Confirm that the display is 05.
FE BIAS VR 1 (V/H version only) FE BIAS VR 2
Optimum eye pattern
[3]
Test disc type 4
Optimum eye pattern
10
|
|
 |
> |
|