Text excerpt from page 33 (click to view)
MAINTENANCE
IMPORTANT INFORMATION The blades on a BioClip unit should be set at 90 degrees to each other. In all other cases the blades can collide and cause serious damage to the cutting unit. 5. Ensure the blades are positioned as set out in the diagram, at 90 degrees to each other, otherwise the belt must be adjusted. When the blade bearings are loose the belt can be moved around to the next tooth. Tighten the nuts enough so that the bearings rest against the cutting hood but still can be moved. Tension the belt by turning the eccentric adjuster on top of the cutting hood. Tighten the nut. Tighten all nuts on the blade bearings. 6. When the belt can be moved 8 mm (5/16") inwards using a force of 7 N (1.5 lb) the belt is adjusted correctly. 7. Fit the protective cover over the belts and replace the parall strut.
Belt change on cutting unit with rear ejection, side ejection, Combi 103 and Combi 112 WARNING! Wear gloves to protect your hands when working with the blades.
On these cutting units with �collision-proof� blades, the blades are driven by one V-belt. Do as follows to change the V-belt: 1. Remove the cutting unit. 2. Undo the bolt on the lift strut and the two screws on the cover. Lift the cover off the cutting unit. 3. Loosen the spring (4) that tensions the V-belt and pry off the belt. Simply reverse the procedure to fit the new belt.