GAS CONNECTION
Hook-up to the gas supply line is accomplished at the manual gas valve, which is furnished with a 3/8" SAE (UNF 5/8" -18) male flare connection. All completed connections should be checked for leaks with soapy water. 2
WARNING
DO NOT use a flame to check for gas leaks. The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than 11 inches water column. When testing the gas supply system at test pressures in excess of 1/2 psig, the refrigerator and its individual shutoff valve must be disconnected from the gas supply piping system. When testing the gas supply system at pressures less than or equal to 1/2 psig, the appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve. In case detailed instructions on the installation and connection to the gas supply are required, contact your dealer or distributor.
FIG. 9
1
Install the two screws in the top frame, the holes are accessible from beneath. After the two screws have been installed, seal the holes in the top frame with a piece of tape. Replace the top decoration panel. Make sure the tabs snap back into the holes in the hinge plate. Third: Two screws installed in the rear base. See FIG. 10.
TESTING LP GAS SAFETY SHUTOFF
The gas safety shutoff must be tested after the refrigerator is connected to the LP gas supply. To test the gas safety shutoff, proceed as follows: 1. Start the refrigerator according to the instructions for Gas Operation. 2. Check that the gas flame is lit. The red indicator D is on the green field, (ON). 3. Close the manual gas shutoff valve by turning the knob A back to "OFF" position. 4. Wait for one minute, then disconnect the 12 volt DC power to the reigniter. 5. Remove protection cover (see FIG. 1) and open the manual gas shutoff valve by turning knob A to the "GAS" position without pushing button C. The reigniter should not be sparking. Apply a non-corrosive commercial bubble solution to the burner jet. Be careful not to damage the burner jet. 6. No bubbles should appear at the opening of the burner jet. The presence of bubbles indicates a defective gas safety shutoff and service is required. 7. If no bubbles were present at the burner jet, the gas safety valve is working properly. Rinse jet thoroughly with fresh water before proceeding. Be careful not to damage the burner jet. Replace the protection cover. Reconnect the 12 volt DC power supply to the reigniter. Start the refrigerator by following the instruction for Gas Operation. Normal operation of the burner should now return. Allow the burner to operate for a minimum of five minutes.
Hole for drain water hose
FIG. 10
Failure to follow the sequence in securing refrigerator in enclosure can cause leakage between the frame and cabinet. Any space between the counter, storage area or ceiling and top of the refrigerator greater than 1-1/2 inches should be blocked. The heat produced at the rear of the refrigerator will become trapped in this space, making the top of the refrigerator hot and reduce the efficiency of the refrigerator.
Drain water hose
A hole must be drilled through flooring see FIG. 10. The hole must be drilled in the cut out opening of the base plate at the rear of the refrigerator. The installer MUST make sure that the hose does not kink when run through the floor. Seal around the hose that goes through the drilled hole. If a longer hose than supplied is required to get the water to drain outside of the vehicle, the installer will have to supply the extra length of hose.