I want to give you a real heads-up for your desire to enable such people as I to acquire the information I need to maintain the older types of equipment such as this Akai HXA351W. You do a swell job with all the processes you have to perform so I can have a legible, thus usable
document which does not send me crazy trying to figure out the blurry text of a bad copy.
Very well done, Thomas.
;
This manual is very well presented and after printing out looks about as close to an original as I think you can get. The quality is second to none.
The content of the manual is comprehensive and I think it would be well suited to an audio repair professional which I'm not but I did find it very informative and helpful.
The cost of the manual is more than covered by the money I'll save when I change the keep memory battery now I have the relavant info.
Very pleased with my purchase and can recommend it wholeheartedly as I can other manuals I've downloaded from this site.
Regards
Limey Alex
;
Complete manual including mechanical part in good pdf quality. Shaded greys of the pcb due to pdf not perfect but usable.
;
Nice pdf file of the manual sent promptly. Thanks.
;
Complete MFG Service Manual at a good price FAST !
RR 640 CD / RR 670 CD
Abgleichvorschriften / Adjustment Procedures
2. Tuner
Messgeräte: Messsender, Wobbelsender, Oszilloskop, Frequenzzähler. Funktionsschalter: Radio Abgleich 1. AM-ZF Vorbereitung Wobbelsender 465kHz über Rahmenantenne in L506 (Ferritantenne) einkoppeln. Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: MW Drehkoanschlag: MW fu 515kHz, fo 1630kHz Messsendersignal über Rahmenantenne in L506 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: MW MW 558kHz, MW 1440kHz Messsendersignal über Rahmenantenne in L506 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: MW Drehkoanschlag: fo 292kHz Messsendersignal über Rahmenantenne in L507 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: LW LW 153kHz, LW 261kHz Messsendersignal über Rahmenantenne in L507 (Ferritantenne) einkoppeln (fmod = 1kHz, m = 30%, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: LW Drehkoanschlag: FM fu 87,35MHz, fo 108,25MHz Messsendersignal über 10nF an Messpunkt TP 1 / TP 2 (Masse) einkoppeln (fmod = 1kHz, �f = 22,5kHz, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: FM FM 88MHz, FM 106MHz Messsendersignal über 10nF an Messpunkt TP 1 / TP 2 (Masse) einkoppeln (fmod = 1kHz, �f = 22,5kHz, Ua nur so gro�, dass das Signal gerade erkennbar ist). Oszilloskop an Messpunkt TP 6 / TP 7 (CN501 Pin 1/3). Bandschalter: FM Messsendersignal keines IC501 zwischen Pin 1 und Pin 29 kurzschlie�en. Frequenzzähler an Messpunkt TP 5 (IC501 Pin 4). Abgleichvorgang Mit T501 auf Maximum einstellen.
2. MW Oszillator
fu (bei 515kHz) mit L504 auf Maximum einstellen. fo (bei 1630kHz) mit VCT501(B) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
3. MW Vorkreis
Bei 558kHz mit L506 (MW-Antennenspule) auf Maximum einstellen (verschieben). Bei 1440kHz mit VCT501(A) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
4. LW Oszillator
fo (bei 292kHz) mit TC502 auf Maximum einstellen.
5. LW Vorkreis
Bei 153kHz mit L507 (LW-Antennenspule) auf Maximum einstellen (verschieben). Bei 261kHz mit TC501 auf Maximum einstellen. Abgleich wechselseitig wiederholen.
6. FM Oszillator
fu (bei 87,35MHz) mit L503 auf Maximum einstellen. fo (bei 108,25MHz) mit VCT501(C) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
7. FM Vorkreis
Bei 88MHz mit L502 auf Maximum einstellen (verbiegen). Bei 106MHz mit VCT501(D) auf Maximum einstellen. Abgleich wechselseitig wiederholen.
8. FM-MPX (Stereo)
Mit VR501 76kHz ± 100Hz einstellen.
TP 6 TP 7
TP 5
TP 2
TP 1
GRUNDIG Service
2-2
|
|
|
> |
|