Who's Online
There currently are 5924 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
El producto satisface las necesidades del servicio t
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
2-5. Copy density adjustment A. When the copy density adjustment is required:
The copy density adjustment must be performed in the following cases:
(2) Drum sensitivity setting
(1) Execute Sim. 26-07, and check that the top digit of the 9-digit drum number printed on the flange in front of the drum is displayed on the copy quantity display. If the displayed number is different from the drum number, change the setting with the 10 digit key pad.
(2)
� �
When maintenance is performed. When the output current of the main charger and the transfer charger, the separation charger bias voltage, or the grid voltage is adjusted. (When the charger unit or the high voltage unit is replaced.)
(Note) When the 10 digit key pad is used to enter a number, the display shows only in the range of 1 � 3.
(3) AE sensor level adjustment
(1) Execute Sim. 47. (The mirror base starts scanning and stops at the AE sensor level measurement position.) Put several sheets of A3 (11" x 17") paper on the original table. Press the PSW again, and the copy lamp will light up and the sensor output will be displayed on the copy quantity display. This output level is stored.
� � � � � � � � �
When the developing bias is adjusted. When any part of the AC PWB unit is replaced. When the AE sensor is replaced. When the copy lamp is replaced. When the optical unit is replaced. When the optical unit is disassembled, repaired, or adjusted. When exposure adjustment plate is moved. When the drum is replaced. When the main PWB is replaced. (2) (3)
B. Note for copy density adjustment � The charger output and the developing bias
adjusted in advance.
voltage are properly
� �
The half-tone uniformity is within the limit sample range. Sim. 44-01 is set to "7."
C. Copy density adjustment procedure
(1) Set the automatic exposure level to "3."