Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
 ;
Exactly what was needed to assess the product - excellent value and great service
 ;
A site where discontinualed schematic diagrams and back dated information can be found on discontinued radios tv's and any electronic equipment can be found. Newer manuals either Service and operating manuals. Radio amateurs should find this site a great source for ham radio equipment manuals. I will return to this site should I need information on any electrical equipment. priced easy to download in a PDF format and print pages need to undertake the repair.
 ;
Quality scan of the original. All the detail necessary to troubleshoot, repair and adjust the unit. I'm sure I will be downloading more manuals in the future as the need arises.
3-4-2. Normal Audio System Adjustment � Make adjustment in the SP mode, unless otherwise specified. Use a normal VHS cassette for an adjustment tape. � Set AUDIO MONITOR to normal. [Adjustment Sequence] 1. 2. 3. 4. ACE Head Adjustment E-E Output Level Check Frequency Responce Check Overall Level Characteristic and Distortion Factor Check 5. Overall S/N Check 1. ACE Head Adjustment Refer to the service manual of VHS MECHANICAL ADJUSTMENT VI. 2. E-E Output Level Check Purpose: Confirm that the output level against the reference input is within the specification. Mode Signal Measurement point Measurement equipment Specified value E-E L, R: 400 Hz, �7.5 dBs Audio output terminal Audio level meter �7.5 ± 2 dBs
4. Overall Level Characteristic and Distortion Factor Check Purpose: Check the record level, play level, and distortion factor against the reference input. Mode Signal Measurement point Measurement equipment Specified value REC and PB (SP mode) 400 Hz, �7.5 dBs Audio output terminal Audio level meter and distortion factor meter Playback level: �7.5 ± 4 dBs Distortion factor: 4% or less
3-6.
PARTS ARRANGEMENT DIAGRAM FOR ADJUSTMENTS
MA-325 BOARD (Side A)
CN501
1 CN341
4
2 1
CT401
Confirmation Method: 1) Supply an audio signal of 400 Hz, �7.5 dBs simultaneously to both L and R channels of Audio Line Input. 2) Make recording 3) Play back a recorded portion. 4) Confirm that a playback level is �7.5 ± 4 dBs. 5) Confirm that a distortion factor is within 4%. 5. Overall S/N Check Purpose: Confirm that the S/N is within the specification. Mode Signal Measurement point Measurement equipment Specified value REC and PB (SP mode) Short Audio output terminal Audio noise meter �46.0 dBs or less
JS161
Confirmation Method: 1) Simultaneously input a signal of 400 Hz, �7.5 dBs to both L and R channels of Audio Line Input. 2) Confirm that the audio output level is �7.5 ± 2 dBs. 3. Frequency Responce Check Purpose: Confirm that the frequency characteristic is within the specification. Mode Signal Measurement point Measurement equipment Specified value REC and PB (SP mode) 400 Hz, �30.0 dBs 7 kHz, �30.0 dBs Audio output terminal Audio level meter 1 ± 4 dB
Confirmation Method: 1) Connect both L and R channels of audio line input to the GND. 2) Start recording. 3) Play the recorded part to confirm that the noise is below �46.0 dBs.
SR-718 BOARD (Side A)
3-5.
3-5-1.
VIDEO SYSTEM ADJUSTMENT
RV201 6V ADJ
Tape path adjustment must have been completed. Confirmation Method: 1) Supply a signal of 400 Hz, �30.0 dBs to both L and R channels of Audio Line Input. 2) Connect the audio level meter to the Audio Line Output. 3) Adjust the attenuator so that the audio level meter will indicate �30.0 dBs. 4) Make recording in the SP mode. 5) Set an audio line input signal to 7 kHz and make recording. 6) Playback a recorded portion, and measure output levels at 400 Hz and 7 kHz. 7) Confirm that the 7 kHz playback output level within a range of the 400 Hz playback output level 1 ± 4 dB.
VCO Oscillation Frequency Adjustment (MA-325 Board) Purpose: Adjust to set the character position on the screen. Mode Signal Measurement point Measurement equipment Adjusting Element Specified value E-E Color bar Pin @§ of IC401 Oscilloscope (DC mode) CT401 2.75 ± 0.05 V
1
CN201 9
VDD = 5.0V 1H
2.75±0.05V GND = 0V
Fig. 7-3-6.
7-5