SM-SX100
FOR A COMPLETE DESCRIPTION OF THE OPERATION OF THIS UNIT, PLEASE REFER TO THE OPERATION MANUAL.
IMPORTANT SERVICE NOTES (FOR U.S.A. ONLY)
BEFORE RETURNING THE AUDIO PRODUCT (Fire & Shock Hazard) Before returning the audio product to the user, perform the following safety checks. 1. Inspect all lead dress to make certain that leads are not pinched or that hardware is not lodged between the chassis and other metal parts in the audio product. 2. Inspect all protective devices such as insulating materials, cabinet, terminal board, adjustment and compartment covers or shields, mechanical insulators etc. 3. To be sure that no shock hazard exists, check for leakage current in the following manner. * Plug the AC line cord directly into a 120 volt AC outlet. * Using two clip leads, connect a 1.5k ohm, 10 watt resistor paralleled by a 0.15µF capacitor in series with all exposed metal cabinet parts and a known earth ground, such as conduit or electrical ground connected to earth ground. * Use a VTVM or VOM with 1000 ohm per volt, or higher, sensitivity to measure the AC voltage drop across the resistor (See diagram). * Connect the resistor connection to all exposed metal parts having a return path to the chassis (antenna, metal cabinet, screw heads, knobs and control shafts, escutcheon, etc.) and measure the AC voltage drop across the resistor.
TO EXPOSED METAL PARTS
VTVM AC SCALE 1.5k ohms 10W
0.15 µ F TEST PROBE
CONNECT TO KNOWN EARTH GROUND
All check must be repeated with the AC line cord plug connection reversed. Any reading of 0.3 volt RMS (this corresponds to 0.2 milliamp. AC.) or more is excessive and indicates a potential shock hazard which must be corrected before returning the audio product to the owner.
IMPORTANT SERVICE NOTES (FOR U.K. ONLY)
Before returning the unit to the customer after completion of a repair or adjustment it is necessary for the following withstand voltage test to be applied to ensure the unit is safe for the customer to use. Setting of Withstanding Voltage Tester and set.
Set name Withstanding Voltage Tester Test voltage Set time Set current(Cutoff current) Unit Judgment OK: The �GOOD� lamp lights. NG: The �NG� lamp lights and the buzzor sounds. 2,120 VPEAK 1,500 VRMS 60 secs 4 mA set value
WITHSTANDING VOLTAGE TESTER
+
AC OUT
PROBE
SHORT-CIRCUIT AC POWER SUPPLY CORD
UNIT CONNECT THE PROBE TO GND OF CHASSIS SCREW