Technical Data, Mechanical data, Detailed Circuit diagram with components value, PCB layout. Actual PCBs Print. Component List, Spare parts code list and Input output detail. It cover LBB1211, LBB1212, LBB1213, LBB1216, LBB1217.
It is the actual Service Manual for SQ10
 ;
very good manual with clear electrical schemes. Very helpful to find wat was wrong inside my microwave.
5- UPPER CORNER CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide pincushion changes from pincushion to barrel shape. c) When volume-down is pressed, slide pincushion changes from barrel to pincushion shape. d) Adjust the UPPER CORNER CORRECTION to obtain condition as in (fig. 5).
6-LOWER CORNER CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide pincushion changes from pincushion to barrel shape. c) When volume-down button is pressed, slide pincushion changes from barrel to pincushion shape. d) Adjust the LOWER CORNER CORRECTION to obtain condition as in (fig. 6).
7- VERTICAL LINEARITY
a) Receive Philips pattern signal. b) When volume-up button is pressed, upper picture scanning decreases and lower picture scanning increase. c) When volume-down button is pressed, upper picture scanning increases and lower picture scanning decreases. d) Adjust the vertical symmetry to obtain symmetrical scanning between upper and lower picture (fig. 7).
8-VERTICAL ANGLE
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical angle changes to the right. c) When volume-down button is pressed, vertical angle changes to the left. d) Adjust the VERTICAL ANGLE to obtain condition as in (fig. 8).
9- VERTICAL BOW
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical bow changes to the right. c) When volume-down button is pressed, vertical bow changes to the left. d) Adjust the VERTICAL BOW to obtain condition as in (fig. 9).
10-VERTICAL AMPLITUDE
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical size of picture increases. c) When volume-down button is pressed, vertical size of picture decreases. d) Adjust the vertical size to obtain overscan (fig. 10).
11-S-CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, upper and lower scanning decreases, and center scanning increases. c) When volume-down button is pressed, upper and lower scanning increases, and center scanning decreases. d) Adjust the S-correction to obtain a balance between upper, lower and center (fig. 11).