Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
Manual was just as described!!! I odered it and in less than a day was able to download it and the text was clear and pages were all complete just as the original manual was. Purcashed this for a friend and they were more than happy. Perfect all around!
 ;
Excellent service and prompt delivery. But it's not a manual - only 4 pages wiring diagrams.
Thanks.
 ;
The manual I purchased was exactly what I needed to repair my Toshica television. The manual contained schematics and troubleshooting information that was very helpful.
 ;
Il download del Service Manual JVC HR 4100 non é stato eseguito
 ;
The Service Manual was just as expected, complete with schematics and I was able to download it in less than an hour after I ordered it. The only problem with these is that the schematics are hard to read due to the small font. I could remedy this by printing them on a larger printer.
5- UPPER CORNER CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide pincushion changes from pincushion to barrel shape. c) When volume-down is pressed, slide pincushion changes from barrel to pincushion shape. d) Adjust the UPPER CORNER CORRECTION to obtain condition as in (fig. 5).
6-LOWER CORNER CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide pincushion changes from pincushion to barrel shape. c) When volume-down button is pressed, slide pincushion changes from barrel to pincushion shape. d) Adjust the LOWER CORNER CORRECTION to obtain condition as in (fig. 6).
7- VERTICAL LINEARITY
a) Receive Philips pattern signal. b) When volume-up button is pressed, upper picture scanning decreases and lower picture scanning increase. c) When volume-down button is pressed, upper picture scanning increases and lower picture scanning decreases. d) Adjust the vertical symmetry to obtain symmetrical scanning between upper and lower picture (fig. 7).
8-VERTICAL ANGLE
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical angle changes to the right. c) When volume-down button is pressed, vertical angle changes to the left. d) Adjust the VERTICAL ANGLE to obtain condition as in (fig. 8).
9- VERTICAL BOW
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical bow changes to the right. c) When volume-down button is pressed, vertical bow changes to the left. d) Adjust the VERTICAL BOW to obtain condition as in (fig. 9).
10-VERTICAL AMPLITUDE
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical size of picture increases. c) When volume-down button is pressed, vertical size of picture decreases. d) Adjust the vertical size to obtain overscan (fig. 10).
11-S-CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, upper and lower scanning decreases, and center scanning increases. c) When volume-down button is pressed, upper and lower scanning increases, and center scanning decreases. d) Adjust the S-correction to obtain a balance between upper, lower and center (fig. 11).
5
MC-Service
|
|
 |
> |
|