This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
5- UPPER CORNER CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide pincushion changes from pincushion to barrel shape. c) When volume-down is pressed, slide pincushion changes from barrel to pincushion shape. d) Adjust the UPPER CORNER CORRECTION to obtain condition as in (fig. 5).
6-LOWER CORNER CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide pincushion changes from pincushion to barrel shape. c) When volume-down button is pressed, slide pincushion changes from barrel to pincushion shape. d) Adjust the LOWER CORNER CORRECTION to obtain condition as in (fig. 6).
7- VERTICAL LINEARITY
a) Receive Philips pattern signal. b) When volume-up button is pressed, upper picture scanning decreases and lower picture scanning increase. c) When volume-down button is pressed, upper picture scanning increases and lower picture scanning decreases. d) Adjust the vertical symmetry to obtain symmetrical scanning between upper and lower picture (fig. 7).
8-VERTICAL ANGLE
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical angle changes to the right. c) When volume-down button is pressed, vertical angle changes to the left. d) Adjust the VERTICAL ANGLE to obtain condition as in (fig. 8).
9- VERTICAL BOW
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical bow changes to the right. c) When volume-down button is pressed, vertical bow changes to the left. d) Adjust the VERTICAL BOW to obtain condition as in (fig. 9).
10-VERTICAL AMPLITUDE
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical size of picture increases. c) When volume-down button is pressed, vertical size of picture decreases. d) Adjust the vertical size to obtain overscan (fig. 10).
11-S-CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, upper and lower scanning decreases, and center scanning increases. c) When volume-down button is pressed, upper and lower scanning increases, and center scanning decreases. d) Adjust the S-correction to obtain a balance between upper, lower and center (fig. 11).
5
MC-Service
|
|
 |
> |
|