Who's Online
There currently are 5798 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Fully functional usable service manual. Considering the age of the manual and device quality was better than expected
;
Thank you very much, I've been very happy to find this manual on "Owner Manual". It's a perfect copy and it has been really useful for my work!
;
It took about 24-hours after my payment before I was able to get to the download. Apparently, payment processing is not 100% automated. That is no big deal, just be aware of that going in.
After I got to it, it was in good shape, easy to read, etc. Not some cheap FAX copy looking thing.
Also, this site was the cheapest I found. Another Plus!
;
Good price, very legible manual, exactly what I needed -- but had to wait a day to actually get the download of the manual. Would have preferred to download it immediately after payment rather than waiting for someone to "process" my order. I was surprised that I had to wait that long.
;
As the only source for this manual it rather rank quite high since it is well scanned and perfectly readable.
6-2. HANDSET SECTION
� Make the set in Test mode (see page 19)
3. Checking TX output Setting:
peak power meter
1. Checking RX I&Q Output Level Setting:
oscilloscope + � level meter + � TP520: RXIP TP521: RXIN TP522: RXQP TP523: RXQN TP553: GND
+ �
ANTENNA TERMINAL
SSG
ANTENNA TERMINAL
Procedure: 1. Place the handset in the Continuous Transmit mode (CH1, High power). 2. Measure the ANT OUT output of the RF module in the handset using a peak power meter. 3. Confirm that the measured output is 80 mW (MIN 20 mW). 4. Also, execute steps 1 through 3 for the channels 10 and 20. CH10: 80 mW (MIN 20 mW) CH20: 50 mW (MIN 10 mW)
Procedure: 1. Place the handset in the Continuous Receive mode (CH1, LNA, AGC ON). 2. Set the SSG frequency to the frequency on CH1 + 300 kHz, and the RF output level to �95 dBm. 3. Measure the output level of RXIN, RXIP, RXQN, and RXQP with a level meter. At this time, confirm with an oscilloscope that a sine wave of 300 kHz is output. 4. Confirm that the measured output level is �31.0 to �24.0 (TYPICAL �27.0) dBV. If IC502 was replaced (there is no ID data), the output level is �31.0 to �24.0 dBV. 5. Also, execute steps 1 through 4 for the channels 10 and 20. * For the frequency on each channel, see page 15.
2. Checking TX Center Frequency Setting: � short: TP555 � TP553
frequency counter + � ANTENNA TERMINAL
Procedure: 1. Short TP555 and TP553 (GND) on the HAND MAIN board in the handset. 2. Place the handset in the Continuous Transmit mode (CH1, High power). 3. Measure the ANT OUT frequency of the RF module in the handset using a frequency counter. 4. Confirm that the measured frequency is 903.600 MHz ± 27 kHz. 5. Also, execute steps 1 through 4 for the channels 10 and 20.