Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 5672 guests online.
Categories
Information
Featured Product
Home >> MARANTZ >> SR5000N1B Service Manual
 
 0 item(s) in your cart 

MARANTZ SR5000N1B
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of MARANTZ SR5000N1B Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 RK100/L JVC Service Manual by Menahem Yachad;
Good quality, clear diagrams. Exactly what I needed.
 KRFX7775D KENWOOD Service Manual by H. Zeilstra;
Good product. All the information is invcluded, but due to the complexity of the amplifier, it still is difficult to get it to operation again.
 STR-6055 SONY Service Manual by Teresa RIGAULT;
Very professional seller; very fast, accurate and rielable service.
 PM730 MARANTZ Service Manual by Michał Graczyk;
great works fine, got the manual on mail within a day
 5016 STEREO GRUNDIG Service Manual by Vaclav Skricka;
First class Service, best quality, come again Thank You. vac

Text excerpt from page 24 (click to view)
6. ADJUSTMENT PROCEDURE
ALIGNMENT INSTRUCTIONS
(1) EQUIPMENT NEEDED AM Standard Signal Generator FM Standard Signal Generator Oscilloscope VTVM (AC,DC) AM Test Loop Antenna (AM Adjustment) FM Dummy Antenna (FM Adjustment) Stereo Signal Generator (RDS IN : EUROPE ONLY) Frequency Counter Distortion Analyser
AM-SG

IMPORTANT 1.Check power-source voltage. 2.Set the function switch to band aligned. 3.Keep the signal input as low as possible to adjust accurately. 4.Modulation and modulation frequency.

(2) FM, AM TRACKING VOLTAGE ADJUSTMENTS
AM,FM DC Voltmeter : Connect to test point TP1 and GND NO Band 1 2 FM AM AM Frequency 87.50 MHz 522 kHz 520 kHz Adjust for 1.6V 1.0V 1.0V Adjustment L7 L13 L13
DC EVM

(4) FM RF ADJUSTMENTS
Signal generator : Connect to FM Ant. (FM 75 ohm) through the dummy. Adjust for indication of VTVM of the wave form of scope to be maximum. Band NO FM 1 3 Frequency 100.10 MHz Adjust for
Max sensitivity

Adjustment L2,L5,L6,T1

Repeat steps 1 several times.
AC EVM OSCILLOSCOPE

Band AM

Item

Modulation 30 %

Modulation freq. 400 Hz 1 kHz

UNIT FM AM GND GND

kHz

FM (EUR, OVC) MONO : 40 kHz DEV. SR5000/N1B STERO : L=R (40 kHz), PILOT (7.5 kHz) 47.5 kHz DEV. SR5000/K1B RDS : STEREO + RDS (1.2 kHz) 48.7 kHz DEV. FM (USA) SR5000/U1B MONO : 75 kHz DEV. (100 %) DTEREO : L=R (67.5 kHz), PILOT (7.5 kHz)

TP1
AM LOOP antenna
60cm OUTPUT terminal

1 kHz

(3) AM RF ADJUSTMENTS
Signal generator : Connect to the AM Ant. Coil through the loop antenna. Adjust for the indication of VTVM of the wave form of scope to be maximum. /N1B, /K1B Band NO 1 AM 2 3

(5) FM MONO DISTORTION ADJUSTMENTS
Signal Generator : Connect to FM Ant. (FM 75 ohm) through the dummy. DC Voltmeter : Connect to TP2(+),TP3(-) through the choke coil (100uH). Distortion Meter : Connect to output L or R.

TUNER ADJUSTMENT POINT

Frequency 612 kHz

Adjust for
Max sensitivity

Adjustment L12,T13 Band NO FM 1 2 3 Frequency Adjust for Adjustment T11 T12

1503 kHz Max sensitivity CT1 Repeat steps 1 and 2 several times.

100.10 MHz DC Voltmeter 0V 100.10 MHz Minimum T.H.D

Repeat steps 1 and 2 several times.
AC EVM OSCILLOSCOPE

/U1B Band NO 1 AM 2 3 Frequency 610kHz 1510 kHz Adjust for
Max sensitivity Max sensitivity

Adjustment L12,T13 CT1

FM-SG
MHz OUT

Repeat steps 1 and 2 several times.
UNIT
DC EVM

FM Dummy

FM-SG
MHz OUT

FM 75ome in
UNIT
TP12 TP13 output Choke coil 100 H

OUTPUT

FM Dummy DISTORTION ANALYSER

FM 75ome in

37

38

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EV-S1000E SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

MECABLITZ 60 CT4 METZ
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.293 - Number of Queries: 139 - Query Time: 0.068