|
Who's Online
There currently are 5949 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.
;
Welcome. The scheme is clearly helped me to repair. Worth to download it.
;
Excellent manual, very clear, technical specification provided, useful information regarding adjustment and set up.
;
fast and easy and exactly what I was looking for. Not the cheapest but value for money after all.
;
The manual for the Sansui P-L75 was not one of the more informative turntable manuals around but for $5 it was helpful enough.
8. With R and YL adjusted to be within each smaller area, check that the luminance points of MG, B, G, and CY are also partly within the range of each color reproduction. When there are spots out of the range, make adjustment by performing steps 4 to 7 so that all the luminance points are within each range.
2-4. Correction of Residual Point Noise
1. Connect one end of the RS-232C cable to the COM (RS-232C) port of the PC and other end to the connector (CN1) on the adjusting tool board. 2. Connect the adjusting tool board (CN205/PC-2001 board) to the camera and turn on the power. 3. Start the PC. 4. After starting the PC, start the adjustment software �BoxCam.exe�.
2-3-6. Writing
1. After completing the adjustment, press the TAB key to make the END button active state. (Refer to Section 23-3, Step 1) 2. After the END key becomes active state, press the Enter key. The writing of adjustment data is executed. The writing will be completed in about 5 seconds. 3. After the message for the completion of writing is displayed, turn off the power of the unit. Press the OK button of the message to clear the message.
4. Disconnect the camera from the harness of the adjusting tool board, then turn on the power of camera to check that the writing of adjustment data has been correctly completed.
5. In �SelectCOM�, select the port to which the RS-232C cable is connected. 6. Click the �Defect Compensation Mode� button. The current data is read from the camera. 7. After completion of the reading, the following message is displayed.
SSC-M183/M183CE/M188CE/M383/M383CE/M388CE SSC-DC193/DC193P/DC198P/DC393/DC393P/DC398P
2-7
|
|
|
> |
|