This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
8. With R and YL adjusted to be within each smaller area, check that the luminance points of MG, B, G, and CY are also partly within the range of each color reproduction. When there are spots out of the range, make adjustment by performing steps 4 to 7 so that all the luminance points are within each range.
2-4. Correction of Residual Point Noise
1. Connect one end of the RS-232C cable to the COM (RS-232C) port of the PC and other end to the connector (CN1) on the adjusting tool board. 2. Connect the adjusting tool board (CN205/PC-2001 board) to the camera and turn on the power. 3. Start the PC. 4. After starting the PC, start the adjustment software �BoxCam.exe�.
2-3-6. Writing
1. After completing the adjustment, press the TAB key to make the END button active state. (Refer to Section 23-3, Step 1) 2. After the END key becomes active state, press the Enter key. The writing of adjustment data is executed. The writing will be completed in about 5 seconds. 3. After the message for the completion of writing is displayed, turn off the power of the unit. Press the OK button of the message to clear the message.
4. Disconnect the camera from the harness of the adjusting tool board, then turn on the power of camera to check that the writing of adjustment data has been correctly completed.
5. In �SelectCOM�, select the port to which the RS-232C cable is connected. 6. Click the �Defect Compensation Mode� button. The current data is read from the camera. 7. After completion of the reading, the following message is displayed.
SSC-M183/M183CE/M188CE/M383/M383CE/M388CE SSC-DC193/DC193P/DC198P/DC393/DC393P/DC398P