Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
It is pretty good. The schematics were covered all components, the manual also provide the parts list . It's useful for the trouble shooting.
;
Very fast service, best quality of the service manual and the schematics
;
This service manual of the old video cassette recorder VT-LC50EM is very good readable even the tiniest numbers (i.e. IC-pins). The circuits are very clear. Many details of the schematic are very good described but in GERMAN language. Many schematic details - but complete at all. Common background information of several details are enclosed and physical knowledge of the TFT liquid crystal display for example. The manual lacks PCB drawings. If you understand german I would recommend this manual for you.
;
Hi, this is a very clear manual, nice copy, not quite up to the standard of the very best available but better than many others. I think the price was especially fair for a hard to find manual and I would certainly use this manual seller again. Recommended.
;
This schema available for me in good condition. I would highly recommend.
1
2
3
4
7.3 AMP BLOCK TROUBLE SHOOTING
The repair flow of the AMP section
A
PowerON After 4 seconds Level is low. A signal from CN481. (Sound from the speakers) no output no Go to SMPS part output Level is low. yes Check the screws OK of D AMP ASSY. Check soldering of IC421,441(B-2) Waveform is not normal.
The LED lights. yes
B
CrossOver 50Hz?
The speaker relay is on. yes Control Assy Input, D AMP Assy yes
no
A
Turn to Bypass and try again.
The 8-pin IC is hot.
no
Solder shorting? no yes
SMPS Assy Voltage of IC32? Less than [ 10V ]
Check other symptoms.
C
Replace the hot IC, since it is no longer serviceable.
Solder correction
Replace IC32.
'+''-' of multi-meter is reverse.
Cases other than 2�4 below. 1
A
D
Check the resistance between G and S of the FETs (Q421, 431, 441, and 451) with the multimeter. "+" is assigned to G and "-" is assigned to S for the multimeter. Multi-meter : ADVANTEST TR6847 or equivalent FET : IRFB23N15D 2 30k� to 40k� 1k to 10k 3 0 to 1k 4
All FETs are O.K.
All FETs are O.K.
FET has been broken.
E
Check soldering at IR2011S (IC421, IC441)
Replace IR2011S (IC421, IC441)
Replace IR2011S located on the same side as the FET with low resistance.
Everything is all right, except for the waveform (resistance of R471 and 472 is 10 ohms or more). Accidental failure mode Everything is all right, except for the relay not being turned on. Although the VOL is minimum, there is output from CN481.
F
Replace R471 and R472 with new ones. Replace Q506 and Q507 with new ones. Solder shorting of VR3141 of the CONTROL Assy.
44
1 2
S-W1EX
3 4
|
|
|
> |
|