|
Who's Online
There currently are 5360 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Great price, Quick delivery, the document was very usefull A+++++++++++++++
;
Thank´s for your help, I already recived these manual from you
;
Thank you for your manual It has the basic things to and i use the Oszi for Longer Time.
THX
;
Actually, I was looking for this information for 3 years!...now thanks to you, the manual is on my hands and of great help, cause I understand now where I was doing wrong connections and wires...excellent, I'll be back to you if in need, thank you.
;
This manual covers the main equipment features only. While it also includes the procedure for saving and loading from the now long obsolete memory cards it does not mention the how to operate with the optional floppy drive interface so I am still at a loss about how to use this! Note that there is a separate manual covering the MIDI interface and programming via the keyboard, not included in this download. You will also need to get hold of this if you want to use the MIDI interface properly. Basically there is little difference between this manual and the free to download manual for the similar PR60 model.
Phenomenon Storage is not possible. Setting the time signature is not possible.
Remedy � The remaining memory capacity of the COMPOSER is 0. � The time signature cannot be changed for a pattern which is currently recorded in the COMPOSER. If you wish to change the time signature, first follow the procedure to clear the memory.
The playback timing of the rhythm pattern is � The QUANTIZE function was on when the pattern was different from the timing with which it was recorded. recorded and the timing was automatically corrected. Set the quantize level to a smaller note unit or to OFF when recording. The Disk Drive produces a noise during recording � This occurs when the Disk Drive is reading a disk. It or playback. does not indicate a problem. When the procedure to load from a disk is per- � When performing the load operation from a disk, the formed, the contents of the keyboard memory are keyboard memory changes to that of the data loaded erased. from the disk. If you wish to preserve a song which is stored in the keyboard memory, save it on a disk before performing the load procedure. Data cannot be exchanged through MIDI terminals. � The switch for the COMPUTER terminal is not set to MIDI. Turn off the power to this instrument and set the switch to MIDI. � Match the channels on the transmitting side and the receiving side. The sound quavers or is distorted. � When the COMPUTER terminal or both the MIDI IN and OUT terminals are connected to a computer, depending on the computer software the received data may be sent back to the instrument just as it is. Because of this the sound generated from the keys and the sound generated from the returned data are both produced, causing undesirable effects, such as the sounds canceling each other out, for example. In this case, either change the software settings to prevent received data from being returned, or set the MIDI LOCAL CONTROL to off. � This sometimes occurs when electrical equipment such as a radio or TV is used near the instrument. Try moving such electrical equipment further away from the instrument. � The sound may be coming from a nearby broadcast station or amateur radio station. If the sound is bothersome, consult your dealer or service center. � This instrument has a built-in power source that heats the cabinet to some degree. This is not an indication of trouble.
Noise from a radio or TV can be heard.
Other MIDI Disk Drive COMPOSER The cabinet becomes warm during use.
|
|
|
> |
|