I AM HIGHLY IMPRESSED BY THE EASE OF USE OF THIS DOWNLOAD SERVICE. INSTRUCTIONS ARE CLEAR AND SIMPLE TO FOLLOW....EVEN BY TECHNOPHOBES SUCH AS MYSELF. THE EMAILS POINT YOU IN THE RIGHT DIRECTION...ITS SO EASY PEASY. THE DOWNLOAD CHOICE OF USER MANUALS IS EXTENSIVE AND I COULD NOT FIND A CHEAPER OR MORE EFFICIENT SERVICE ON THE INTERNET. I COULD NOT HAVE MADE A BETTER CHOICE OF INFORMATION PROVIDER. SHOULD I EVER NEED ANOTHER USER MANUAL, THEN THIS IS THE FIRST CHOICE SITE. COULD NOT BE BETTER PLEASED!!!!!!!...MANY THANXES FROM JIM BURNS
I was impressed with the quality of service (frequent e-mails to let you know the status of your order), and the speed at which the download became available. The manual was a life saver and was not easy to track down. Thank you for such an excellent service.
the manual was just what i wanted it had all the revelent information required to operate the hifi .Iwould use any manual i downloaded for any item which needs a manual
GOOD SERVICE MANUAL GOT ALL THE INFO. THAT I NEEDED..
Text excerpt from page 36 (click to view)
Installation
How to calculate the effective duct length
The overall duct length will determine the duct diameter. ^ Measure the actual duct length needed to go from the dryer�s exhaust connection to the vent outlet: 1. Establish the number of elbows or bends necessary, noting the type of bend, angle and radius involved (see Table). 2. Add the additional duct length (as derived by using the values specified in the table) and the actual duct length to get the effective length. Note: Maximum effective duct lengths: 4" (100 mm) diameter 66 ft (20 m) 5" (125 mm) diameter 132 ft (40 m) 6" (150 mm) diameter 328 ft (100 m) Using the ring adapter up to an effective duct length of 33 ft (10 m) and a standard duct diameter of 4" (100 mm) will provide optimal drying times and energy consumption. Do not use the ring adapter if the effective duct length is more than 33 ft (10 m). Effective duct lengths over 66 ft (20 m) require a larger duct diameter. Longer ducts may lead to slight decreases in dryer efficiency if the necessary duct diameter is not employed.
Tips about the ductwork
� Check with your local building code to determine the maximum allowable duct length. � Use flexible metal pipe or rigid metal pipe for venting. Non-metallic flexible hose should not be used, it is a potential fire hazard. � For best drying results avoid extra long ducting with too many bends, angles or tight corners. � The shorter the exhaust ductwork, the more efficient the dryer will be. Expelled air is slowed down in the ducts due to friction against the inner walls. The shorter and smoother the inner walls are, the less friction will be created. � An elbow or bend creates more friction than a straight duct. An additional duct length factor must be added for each elbow or bend (see Table). This factor expresses the resistance of the bend in terms of a straight length of duct. The additional length factor is then added to the existing duct to give the effective length. A larger duct diameter helps reduce friction. Therefore the duct diameter and length should be increased simultaneously.