El producto satisface las necesidades del servicio t
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
TK-8108H
REALIGNMENT
4. Clone Mode
Programming data can be transferred from one radio to another by connecting them via their modular microphone jacks. The operation is as follows (the transmit radio is the master and the receive radio is the slave).
5. Accessory Connection Cable (KCT-39)
The KCT-39 is an accessory connection cable for connecting external equipment. The connector has 15 pins and the necessary signal lines are selected for use.
5-1. Installing the KCT-39 in the Transceiver Note :
1. 2. 3. 4. Clone mode should enabled. Turn the master TK-8108H power ON with the [1] key held down. The TK-8108H [�] LED is turned on. Power on the slave TK-8108H. Connect the cloning cable (No. E30-3382-05) to the modular microphone jacks on the master and slave. Press the [�] key on the master TK-8108H transceiver. The data of the master is sent to the slave. While the mas1. Lift the DC cord bushing ( 1 ) from the chassis. Peel the pad as shown in Figure 3 ( 2 ).
1 2
ter is sending data, [TX] LED blinked. While the slave is receiving the data, 4 LEDs, [MON] LED, [�] LED are turned on and [BUSY] LED blinked. When cloning of data is completed, the master [TX] LED turned off, and the slave automatically operates in the User mode. The slave can then be operated by the same program as the master. 5. The other slave can be continuously cloned. Carry out the operation in step 2 to 4.
Fig. 3 4-1. Adding the data password.
If the data password is set in the optional feature menu, you must enter the password (Master transceiver) to activate a clone mode. you can use 1, 2, 3, and 4 to configure the password. The maximum length of the password is 10 digits. 1. 2. 3. 4. 5. [1]+Power ON. [1]~[4] LED, and MON LED are turned ON. Enter the password using [1]~[4] keys. Press [MON] key. If the password matches, the transceiver enters a clone mode. Otherwise, transceiver beeps and returns to the password input mode. 2. Stick the pad to the DC cord ( 3 ) and chassis ( 4 ), both of which are supplied with the KCT-39.