(4) Select [Front] button first, and select R,G or B button. (When you adjust the R level, then select RVCOM)
(8) Change the internal signal patern. Set the white level 50% and press [OK] button.
(9) Select [Front] button, and select [NRSH] button.
(5) Push [+1] or [-1] button, change data and look for the point with which a flicker serves as the minimum. If you push [+4] or [-4] button, the data moves fast. (6) Nxt, select [Ceiling] button, and select R,G or B button.
(10) Push [+1] or [-1] button, change data and look for the point with which a vertical stripe serves as the minimum. If you push [+4] or [-4] button, the data moves fast. (11) After adjusting, push [Save] button .
(7) After adjusting, push [Save] button .
1-36
|