Step
Figure
Explanation
(1) Monitor the waveform at the test point "TP-R". (2) Click [WM7] button and adjust to the specified level.
4
(3) Check the voltage at the test points "TP-R" and "TP-B". (4) Click [Next] button. [Note] "G" and "B" levels also change when [WM7] adjustment is performed.
(1) Monitor the waveform at test point "TP-R". (2) Click [W03] button and adjust to the specified level. ( [W09] and [W0C] are the same process.) (3) Click [Next] button.
5
(1) Monitor the waveform at test point "TP-G". (2) Click [W04] button and adjust to the specified level. ( [W0A] and [W0D] are the same process.)
6
(3) Click [Next] button.
(1) Monitor the waveform at test point "TP-B". (2) Click [W05] button and adjust to the specified level. ( [W0B] and [W0E] are the same process.)